A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ventricular tachyarrhythmias in patients receiving an implantable cardioverter-defibrillator for primary versus secondary prophylaxis indications. | LitMetric

Introduction: Data on the mechanisms of sudden cardiac death are limited and may be biased by delays in rhythm recording and selection bias in survivors. As a result, the relative contributions of monomorphic ventricular tachycardia (VT) (cycle length [CL] > 260 ms), monomorphic fast VT (FVT) (CL ≤ 260 ms), and polymorphic VT (PMVT)/ventricular fibrillation (VF) have not been well characterized nor compared in patients with and without prior arrhythmic events.

Methods: A retrospective cohort study of implantable cardioverter-defibrillator (ICD) recipients with primary or secondary implant indications was used to evaluate intracardiac electrograms (EGMs) for the first spontaneous VT/VF resulting in appropriate ICD therapy. EGMs were categorized into VT, FVT, and PMVT/VF based on CL and morphologic criteria.

Results: Of 616 implants, 145 patients (58 [40%] primary indications) received appropriate ICD therapy for VT/VF over mean follow-up of 3.8 ± 3.2 years. Primary implants had more diabetes (28% vs 12%; P = 0.02) and less antiarrhythmic use (15% vs 33%; P = 0.02). In those patients with spontaneous arrhythmia, PMVT/VF occurred in 20.7% of primary versus 21.8% of secondary implants, FVT in 19.0% versus 21.8%, and VT in 60.3% versus 56.4%, respectively (P = 0.88). Spontaneous VT CL was similar regardless of implant indication (284 ± 56 [primary] vs 286 ± 67 ms [secondary]; P = 0.92).

Conclusions: Monomorphic VT is the most common cause of appropriate ICD therapy regardless of implant indication. These results provide insight into the mechanisms of sudden cardiac death and have implications for the use of interventions designed to limit ICD shocks.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.2010.03004.xDOI Listing

Publication Analysis

Top Keywords

appropriate icd
12
icd therapy
12
implantable cardioverter-defibrillator
8
primary versus
8
mechanisms sudden
8
sudden cardiac
8
cardiac death
8
versus 218%
8
implant indication
8
primary
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!