The rotating wall machine, a basic plasma physics experimental facility, has been constructed to study the role of electromagnetic boundary conditions on current-driven ideal and resistive magnetohydrodynamic instabilities, including differentially rotating conducting walls. The device, a screw pinch magnetic geometry with line-tied ends, is described. The plasma is generated by an array of 19 plasma guns that not only produce high density plasmas but can also be independently biased to allow spatial and temporal control of the current profile. The design and mechanical performance of the rotating wall as well as diagnostic capabilities and internal probes are discussed. Measurements from typical quiescent discharges show the plasma to be high β (≤p>2μ(0)/B(z)(2)), flowing, and well collimated. Internal probe measurements show that the plasma current profile can be controlled by the plasma gun array.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.3505487DOI Listing

Publication Analysis

Top Keywords

rotating wall
12
wall machine
8
ideal resistive
8
resistive magnetohydrodynamic
8
boundary conditions
8
current profile
8
plasma
6
rotating
4
machine device
4
device study
4

Similar Publications

Mass production of biomedical microrobots demands expensive and complex preparation techniques and versatile biocompatible materials. Learning from natural bacteria flagella, the study demonstrates a magnetic polymer multilayer cylindrical microrobot that bestows the controllable propulsion upon an external rotating magnetic field with uniform intensity. The magnetic microrobots are constructed by template-assisted layer-by-layer technique and subsequent functionalization of magnetic particles onto the large opening of the microrobots.

View Article and Find Full Text PDF

Background: In medial mobile-bearing unicompartmental knee arthroplasty (MB-UKA), the position of the bearing does not correspond to the planned position which will increasing the risk of bearing dislocation. This study aimed to explore the relationship between the malposition of the femoral and tibial components and the phenomenon of bearing deviation using postoperative radiological measurements.

Methods: One hundred twenty patients who underwent mobile-bearing uni-compartmental knee arthroplasty (MB-UKA) at our hospital between January and August 2023 were enrolled in this retrospective study.

View Article and Find Full Text PDF

Rotablator-associated coronary perforation can be fatal if bailout is delayed. Successful bailout is typically defined as the disappearance of contrast extravasation after a haemostatic intervention. We report a case of recurrent cardiac tamponade in the subacute phase, wherein haemostasis appeared to have been achieved on angiography following the implantation of a covered stent during the index procedure.

View Article and Find Full Text PDF

Development of Electrospinning Setup for Vascular Tissue-Engineering Application with Thick-Hierarchical Fiber Alignment.

Tissue Eng Regen Med

January 2025

College of Materials Science and Engineering, Hunan University, Changsha, 410072, People's Republic of China.

Background: Tissue engineering holds promise for vascular repair and regeneration by mimicking the extracellular matrix of blood vessels. However, achieving a functional and thick vascular wall with aligned fiber architecture by electrospinning remains a significant challenge.

Methods: A novel electrospinning setup was developed that utilizes an auxiliary electrode and a spring.

View Article and Find Full Text PDF

Purpose: Although idiopathic scoliosis is a common three-dimensional deformity, there is a lack of studies evaluating the associations between the aortic-vertebral distance (AVD) and spinal deformities in all planes. The study therefore aimed to evaluate how the coronal and sagittal curvature, vertebral rotation and aortic-vertebral angle (AVA) affect the AVD in idiopathic scoliosis.

Methods: The AVD, AVA, vertebral rotation and curve angles were measured on preoperative magnetic resonance imaging and radiographs in 46 patients who underwent posterior spinal fusion with pedicle screw instrumentation for idiopathic scoliosis Lenke types 1 and 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!