We investigated the feasibility and potential limitations of estimating bone mineral density (BMD) from standard diagnostic computed tomography (dCT). We analyzed three sets of BMD measurements for L1 and L2, each performed by a novice and an expert, for intra- and interobserver variance (n=43 studies from 38 patients; median age, 13.2 years) using one BMD quantification system with (conventional quantitative computed tomography (QCT)) and two without (QCT and dCT) an external calibration phantom. Using ANOVA model, means of three sets of BMD measurements analyzed by the expert differed by 2.5mg/cm(2); for the novice, by less than 1mg/cm(2). Variation of measurement differences was less for the expert. Mean intra- and interobserver absolute standardized differences (ASD) were 1.77% and 1.8%, respectively. The mean ASD between phantom and phantom-less methods of QCT studies were 3.3%; mean ASD of phantom QCT versus phantom-less dCT was 14.3%. Regression modeling suggested compensation for sources of dCT BMD measurement bias can reduce the mean ASD of phantom QCT versus phantom-less dCT to 6.5%. Thus, phantom-less QCT of dCT adds clinically useful BMD information not typically attained from dCT, thereby augmenting patient care and presenting important possibilities for research without need for additional study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4780050PMC
http://dx.doi.org/10.1016/j.bone.2010.12.012DOI Listing

Publication Analysis

Top Keywords

asd phantom
12
bone mineral
8
mineral density
8
computed tomography
8
three sets
8
sets bmd
8
bmd measurements
8
expert intra-
8
intra- interobserver
8
qct dct
8

Similar Publications

A dedicated cone-beam breast computed tomography (BCT) using a high-resolution, low-noise detector operating in offset-detector geometry has been developed. This study investigates the effects of varying detector offsets and image reconstruction algorithms to determine the appropriate combination of detector offset and reconstruction algorithm.Projection datasets (300 projections in 360°) of 30 breasts containing calcified lesions that were acquired using a prototype cone-beam BCT system comprising a 40 × 30 cm flat-panel detector with 1024 × 768 detector pixels were reconstructed using Feldkamp-Davis-Kress (FDK) algorithm and served as the reference.

View Article and Find Full Text PDF

Propagation-based X-ray phase-contrast computed tomography (PB-PCCT) has been increasingly popular for distinguishing low contrast tissues. Phase retrieval is an important step to quantitatively obtain the phase information before the tomographic reconstructions, while typical phase retrieval methods in PB-PCCT, such as homogenous transport of intensity equation (TIE-Hom), are essentially low-pass filters and thus improve the signal to noise ratio at the expense of the reduced spatial resolution of the reconstructed image. To improve the reconstructed spatial resolution, measured phase contrast projections with high edge enhancement and the phase projections retrieved by TIE-Hom were weighted summed and fed into an iterative tomographic algorithm within the framework of the adaptive steepest descent projections onto convex sets (ASD-POCS), which was employed for suppressing the image noise in low dose reconstructions because of the sparse-view scanning strategy or low exposure time for single phase contrast projection.

View Article and Find Full Text PDF

A TV-minimization image-reconstruction algorithm without system matrix.

J Xray Sci Technol

March 2022

School of Computer and Information Technology, Shanxi University, Taiyuan, Shanxi, China.

Purpose: Total Variation (TV) minimization algorithm is a classical compressed sensing (CS) based iterative image reconstruction algorithm that can accurately reconstruct images from sparse-view projections in computed tomography (CT). However, the system matrix used in the algorithm is often too large to be stored in computer memory. The purpose of this study is to investigate a new TV algorithm based on image rotation and without system matrix to avoid the memory requirement of system matrix.

View Article and Find Full Text PDF

In proton therapy, the knowledge of the proton stopping power, i.e. the energy deposition per unit length within human tissue, is essential for accurate treatment planning.

View Article and Find Full Text PDF

A simple and fast ASD-POCS algorithm for image reconstruction.

J Xray Sci Technol

October 2021

School of Computer and Information Technology, Shanxi University, Taiyuan, Shanxi, China.

Purpose: The adaptive steepest descent projection onto convex set (ASD-POCS) algorithm is a promising algorithm for constrained total variation (TV) type norm minimization models in computed tomography (CT) image reconstruction using sparse and/or noisy data. However, in ASD-POCS algorithm, the existing gradient expression of the TV-type norm appears too complicated in the implementation code and reduces image reconstruction speed. To address this issue, this work aims to develop and test a simple and fast ASD-POCS algorithm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!