Object: The authors performed a study to determine the optimal iliac screw size, length, and trajectory that produce the highest insertional torques.
Methods: Ten fresh cadavers were used and 7.5 × 140-mm and 9.5 × 140-mm iliac screws were placed using 3D image guidance in a randomized fashion in 1 of 2 trajectories. The screws were inserted from the posterior superior iliac spine (PSIS) to either 1) supraacetabular bone or 2) the anterior inferior iliac spine (AIIS). Insertional torque was measured for each full revolution, and the concomitant depth for each torque measurement was recorded. Insertional torque was correlated with detailed bony anatomy.
Results: There was no difference in mean peak insertional torque between the 2 trajectories (25.6 ± 16.4 in-lb [supraacetabular], 26.3 ± 18.2 lb-in [AIIS]; p = 0.8). However, there was a difference between the 2 screw diameters (21.1 ± 10.9 lb-in [7.5-mm-diameter screw], 33.7 ± 19.4 lb-in [9.5-mm-diameter screw]; p = 0.0003). The greatest mean peak insertional torques were observed at depths greater than 80 mm (12.7 ± 9.6 lb-in [≤ 80 mm], 23.7 ± 15.7 lb-in [> 80 mm]; p = 2.6 × 10(-7)). Insertional torque peaks correlated with engagement of the lateral iliac cortex and the superior iliac fossa.
Conclusions: Although the trajectory had no effect on insertional torque, increased torques are achievable by placing larger-diameter and longer screws in proximity to bony landmarks, most of which are at distances greater 80 mm from the entry point at the PSIS. Iliac screws longer than those commonly used in clinical practice can be safely and accurately placed using image guidance, and reproducible screw paths can be achieved.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/2010.9.SPINE10254 | DOI Listing |
J Craniofac Surg
December 2024
Department of Oral and Maxillofacial Surgery, College of Dentistry, King Saud University.
Objectives: This study aimed to evaluate the osseointegration properties of titanium bone implants coated with carob-mediated calcium hydroxide nanoparticles biomechanically, radiographically, and histologically on rabbit tibias.
Material And Methods: Forty coated and forty uncoated titanium alloy bone implants were inserted into 20 New Zealand rabbits; each tibia received 2 implants. The rabbits were sacrificed after 4 or 8 weeks, and samples were retrieved for biomechanical evaluation through removal torque test to assess the bond between implant and bone, radiographic evaluation through microcomputed tomography analysis to compare the bone-to-implant contact percentage and bone volume of the peri-implant area, scanning electron microscopic and histologic evaluation through hematoxylin and eosin stain.
Front Bioeng Biotechnol
December 2024
Department of Spine Surgery, The Affiliated Hospital of Qingdao University, Qindao, China.
Background: Lumbar degenerative diseases are an important factor in disability worldwide, and they are also common among the elderly population. Stand-Alone Oblique Lumbar Interbody Fusion (Stand-Alone OLIF) is a novel surgical approach for treating lumbar degenerative diseases. However, long-term follow-up after surgery has revealed the risk of endplate collapse associated with Stand-Alone OLIF procedures.
View Article and Find Full Text PDFEur J Orthod
December 2024
Department of Dentistry, All India Institute of Medical Sciences, Basni Industrial Area Phase-2, Jodhpur- 342005, Rajasthan, India.
Background: The infrazygomatic miniscrew implants (IZC-MSI) serve as innovative temporary anchorage devices placed parallel to the roots of molars in the infrazygomatic crest region, leveraging their extra-radicular location to support the en masse distalization and intrusion of the maxillary dentition. The efficacy and stability of these screws are crucial for their application in contemporary orthodontic practices.
Objectives: This systematic review aimed to estimate the success rate and factors affecting the stability of IZC-MSI.
Adv Sci (Weinh)
December 2024
School of Electronic Science and Engineering, Nanjing University, Nanjing, 210023, China.
The prevailing research emphasis has been on reducing the critical switching current density (J) by enhancing the damping-like efficiency (β). However, recent studies have shown that the field-like efficiency (β) can also play a major role in reducing J. In this study, the central inversion asymmetry of Pt-Co is significantly enhanced through interface engineering at the sub-atomic layer of Ta, thereby inducing substantial alterations in the β associated with the interface.
View Article and Find Full Text PDFClin Implant Dent Relat Res
December 2024
Department of Medical, Surgical and Health Sciences, University of Trieste, Trieste, Italy.
Introduction: Short implants are today a reliable, minimally invasive option for the rehabilitation of the posterior maxilla. However, maintaining marginal bone stability remains a crucial factor for long-term success, particularly in the case of short implants. The present multicenter prospective case-control study aimed to compare the clinical outcomes of bone-level and tissue-level short implants in the posterior maxilla, focusing on implant survival and peri-implant marginal bone stability over 1 year of function.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!