The aim of this study was to determine size, shape and position of the image layer by evaluation of the radiographic image formation in different anatomic positions. A customized phantom was made of a rectangular acrylic plate measuring 14 cm² and 0.3 cm thick, with holes spaced 0.5 cm away and arranged in rows and columns. Each column was separately filled with 0.315 cm diameter metal spheres to acquire panoramic radiographs using the Orthopantomograph OP 100 unit. The customized phantom was placed on the mental support of the device, with its top surface kept parallel to the horizontal plane, and was radiographed at three different heights from the horizontal plane, i.e., the orbital, occlusal and mandibular symphysis levels. The images of the spheres were measured using a digital caliper to locate the image layer. The recorded data were analyzed statistically by the Student'-t test, ANOVA and Tukey' test (?=0.05). When the image size of spheres in horizontal and vertical axes were compared, statistically significant differences (p<0.05) were observed in all areas, portions of the image layer and heights of horizontal plane evaluated. In the middle portion of the image layer, differences in the image size of spheres were observed only along the horizontal axis (p<0.05), whereas no differences were observed along the vertical axis (p>0.05). The methodology used in this determined the precise size, shape and position of the image layer and differences in magnification were observed in both the horizontal and vertical axes.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s0103-64402010000500014DOI Listing

Publication Analysis

Top Keywords

image formation
8
formation anatomic
8
anatomic positions
8
image layer
8
customized phantom
8
horizontal plane
8
image
5
evaluation panoramic
4
panoramic image
4
positions aim
4

Similar Publications

Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.

View Article and Find Full Text PDF

Conventional kinesin protein is a prototypical biological molecular motor that can step processively on microtubules towards the plus end by hydrolyzing ATP molecules, performing the biological function of intracellular transports. An important characteristic of the kinesin is the load dependence of its velocity, which is usually measured by using the single molecule optical trapping method with a large-sized bead attached to the motor stalk. Puzzlingly, even for the same kinesin, some experiments showed that the velocity is nearly independent of the forward load whereas others showed that the velocity decreases evidently with the increase in the magnitude of the forward load.

View Article and Find Full Text PDF

Analysis of the effect of platelet function and different doses of ticagrelor after flow diverter treatment of intracranial aneurysms.

Neurosurg Rev

January 2025

Neurosurgery Center, Department of Cerebrovascular Surgery, Engineering Technology Research Center of Education Ministry of China on Diagnosis and Treatment of Cerebrovascular Disease, Zhujiang Hospital, Southern Medical University, Guangzhou, China.

Ticagrelor has become the standard drug for the treatment of intracranial aneurysms (IAs) with flow diverters (FDs), but the dosage has not been standardized. The effect of platelet function on clinical and imaging prognosis remains unclear. This study aimed to show the effects of different doses of ticagrelor and platelet aggregation function on the clinical and imaging prognosis after FDs treatment of aneurysms.

View Article and Find Full Text PDF

Objective: Total hip arthroplasty through the Hardinge approach damages the hip abductor muscles. MRI can be used to assess adverse postoperative events. In this prospective randomized controlled trial, we evaluated MRI findings and whether platelet-rich plasma affected postoperative healing of the gluteal muscles (gluteus medius and minimus).

View Article and Find Full Text PDF

To address the challenges of high computational complexity and poor real-time performance in binocular vision-based Unmanned Aerial Vehicle (UAV) formation flight, this paper introduces a UAV localization algorithm based on a lightweight object detection model. Firstly, we optimized the YOLOv5s model using lightweight design principles, resulting in Yolo-SGN. This model achieves a 65.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!