This in vitro study evaluated the effect of different apicoectomy angles, instruments used in root-end preparation, and dental materials used in retrofilling on apical sealing. Root ends were resected at 45 or 90 degrees in 80 single-rooted teeth. For each type of apicoectomy, root-end cavities were prepared with either a round carbide #2 bur or an S12/90D ultrasonic tip. The root-end cavities in each subgroup (apicoectomy + root-end preparation) were filled with silver amalgam without zinc (Am) or with gray mineral trioxide aggregate -Angelus (MTA), and the specimens were immediately immersed in 0.2% rhodamine B for 24 h. Sealing was evaluated based on the dyed cross-sectional dentin area. Data were analyzed statistically by the Kruskal-Wallis test at 5% significance level. No group showed complete sealing of root-end areas. The only significant factor affecting microleakage was dental material, with MTA exhibiting less leakage.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/s0103-64402010000500007 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!