The digital rectal examination scoring system (DRESS).

Dis Colon Rectum

The Division of Colon and Rectal Surgery, Tufts Medical Center, Boston, Massachusetts 02111, USA.

Published: December 2010

Purpose: Assessment of anal sphincter tone is a critical part of anorectal examination, yet no standardized, quantifiable method for describing anal sphincter tone on digital rectal examination exists. We developed a novel scoring system for anal sphincter tone using a scale of 0 to 5 for both resting pressure and squeeze pressure. The score ranges from 0 = no discernable pressure to 5 = extremely tight and 3 = normal. We hypothesized that the digital rectal examination scoring system (DRESS) score would correlate with anorectal manometry pressures.

Methods: Three hundred three patients (mean age, 51 y; range, 28-86 y) who had a DRESS score and a concurrent manometry test (1998-2008) were identified from a prospective database. Means of 4 quadrant manometry at rest and with squeeze were compared with the resting pressure and squeeze pressure DRESS scores at each point from 0 to 5. Box plots for manometry results by DRESS score were graphed. ANOVA using a significance level of α = .05 tested whether each of the DRESS scores were different from one another. Spearman rank correlation coefficients assessed associations between manometry and DRESS results.

Results: Manometric pressures (mmHg; mean ± SEM) for DRESS resting pressure values 0 to 5 were 20.6 ± 2.1, 38.5 ± 2.0, 47.8 ± 1.6, 72.3 ± 1.5, 94.4 ± 2.9, and 128.0 ± 6.7, respectively. Pressures for DRESS squeeze pressure values 0 to 5 were 45.9 ± 5.6, 66.5 ± 3.2, 108.2 ± 4.9, 156.3 ± 4.5, 238.6 ± 9.8, and 368.2 ± 49.1. Box plots demonstrated clear differences between each DRESS score and positive progression from 0 to 5 for both resting pressure and squeeze pressure. ANOVA analysis showed a significant difference in mean manometry measurements at all levels of digital rectal examination, both for resting pressure and squeeze pressure (P < .001). Spearman rank correlations showed a strong positive correlation between the DRESS values and manometry pressures with coefficients of 0.82 for resting pressure and 0.81 for squeeze pressure.

Conclusions: The DRESS score correlated very well with manometry pressures for resting pressure and squeeze pressure. The DRESS system may be a useful description of anal sphincter resting pressure and squeeze pressure in the clinical setting. Further validation may support adoption of the DRESS system as part of the standard anorectal examination.

Download full-text PDF

Source
http://dx.doi.org/10.1007/DCR.0b013e3181f23c85DOI Listing

Publication Analysis

Top Keywords

resting pressure
32
squeeze pressure
28
pressure squeeze
24
dress score
20
digital rectal
16
rectal examination
16
anal sphincter
16
pressure
16
dress
14
scoring system
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!