The Cobas TaqMan MTB test, based on real-time PCR technology, was evaluated for direct detection of Mycobacterium tuberculosis complex (MTBC) in respiratory specimens. A total of 1,093 samples from 446 patients, including 118 acid-fast smear-positive and 975 acid-fast smear-negative specimens, were investigated. Diagnostic cultures performed with 7H11 agar, Löwenstein-Jensen medium, and the Bactec MGIT 960 system were considered the reference methods. When discrepant results between the Cobas TaqMan MTB test and culture occurred, additional results from the BD MGIT TBc identification test and the GenoType Mycobacterium CM test performed on growth-positive and acid-fast-stain-positive MGIT tubes and review of the patient's medical history were used for discrepancy analysis. The overall sensitivity, specificity, positive predictive value, and negative predictive value for the Cobas TaqMan MTB test were 91.5%, 98.7%, 91.5%, and 98.7%, respectively. In general, the performance of the new Cobas TaqMan MTB test was comparable to that of the replaced Cobas Amplicor MTB system. The most prominent feature of the new system was its extraordinarily high sensitivity (79.5%) for detecting MTBC in smear-negative specimens; out of 44 smear-negative but culture-positive specimens, 35 were positive by the new system. The Cobas TaqMan MTB assay, including DNA extraction, can be completed within 3 h.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3067742PMC
http://dx.doi.org/10.1128/JCM.01839-10DOI Listing

Publication Analysis

Top Keywords

cobas taqman
24
taqman mtb
24
mtb test
20
direct detection
8
detection mycobacterium
8
mycobacterium tuberculosis
8
tuberculosis complex
8
respiratory specimens
8
smear-negative specimens
8
915% 987%
8

Similar Publications

Background: Point-of-care HIV viral load testing may enhance patient care and improve HIV health services. We aimed to evaluate the feasibility and acceptability of implementing such testing in a high-volume community sexual health clinic in the United States.

Methods: We conducted a cross-sectional, mixed-methods study.

View Article and Find Full Text PDF

Objective: According to the YY/T 1182-2010 standard of the People's Republic of China on nucleic acid amplification test reagents (kits) for medical industry, the accuracy, precision, linear range, and analytic sensitivity of HIV-1 standardized quality control products should be assessed. The Geneway HIV-1 Nucleic Acid Detection Kit from China has been successfully registered with the National Medical Products Administration. Here, we aimed to assess for the first time its detection performance.

View Article and Find Full Text PDF

The GeneXpert HBV Viral Load test is a simplified tool to scale up screening and HBV monitoring in resource-limited settings, where HBV is endemic and where molecular techniques to quantify HBV DNA are expensive and scarce. However, the accuracy of field diagnostics compared to gold standard assays in HBV-endemic African countries has not been well understood. We aim to validate the diagnostic performance of the GeneXpert HBV Viral Load test in freshly collected and stored plasma and dried blood spot (DBS) samples to assess turn-around-time (TAT) for sample processing and treatment initiation, to map GeneXpert machines and to determine limitations to its use in The Gambia.

View Article and Find Full Text PDF

Background: The WHO HIV testing algorithm for high prevalence populations recommends the use of three different serologic assays, though this approach may lead to diagnostic misclassification. The study objective was to compare dried blood spot (DBS)-based HIV-1 nucleic acid detection methods to determine their suitability to confirm the diagnosis of HIV-1 in adults generally with suppressed or low-level plasma HIV-1 RNA.

Methods: Four methods were evaluated: Cepheid Xpert HIV-1 Qual Assay (Xpert), Hologic Aptima HIV-1 Quant Dx assay (Aptima), Roche Cobas Ampliprep/Cobas TaqMan HIV-1 test, v.

View Article and Find Full Text PDF

HIV RNA plasma viral load (VL) is the standard surrogate marker to monitor response to antiretroviral treatment (ART). We compared the linearity, repeatability, and concordance of six commercially available HIV RNA VL platforms using clinical samples from patients from Brazilian sites where different HIV-1 subtypes co-circulate. A total of 150 plasma samples from each city were collected in Curitiba, Southern Brazil (subtype C), São Paulo (subtype B), and Santos (BF recombinants), Southeast Brazil.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!