The ionic liquid SLB-IL111 column, available from Supelco Inc., is a novel fused capillary gas chromatography (GC) column capable of providing enhanced separations of fatty acid methyl esters (FAMEs) compared to the highly polar cyanopropyl siloxane columns currently recommended for the separation of cis- and trans isomers of fatty acids (FAs), and marketed as SP-2560 and CP-Sil 88. The SLB-IL111 column was operated isothermal at 168°C, with hydrogen as carrier gas at 1.0 mL/min, and the elution profile was characterized using authentic GC standards and synthetic mono-unsaturated fatty acids (MUFAs) and conjugated linoleic acid (CLA) isomers as test mixtures. The SLB-IL111 column provided an improved separation of cis- and trans-18:1 and cis/trans CLA isomers. This is the first direct GC separation of c9,t11- from t7,c9-CLA, and t15-18:1 from c9-18:1, both of which previously required complimentary techniques for their analysis using cyanopropyl siloxane columns. The SLB-IL111 column also provided partial resolution of t13/t14-18:1, c8- from c6/c7-18:1, and for several t,t-CLA isomer pairs. This column also provided elution profiles of the geometric and positional isomers of the 16:1, 20:1 and 18:3 FAMEs that were complementary to those obtained using the cyanopropyl siloxane columns. However, on the SLB-IL111 column the saturated FAs eluted between the cis- and trans MUFAs unlike cyanopropyl siloxane columns that gave a clear separation of most saturated FAs. These differences in elution pattern can be exploited to obtain a more complete analysis of complex lipid mixtures present in ruminant fats.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2010.11.072 | DOI Listing |
Anal Chim Acta
November 2019
Australian Centre for Research on Separation Science, School of Chemistry, Monash University, Wellington Road, Clayton, VIC, 3800, Australia. Electronic address:
This study develops analytical approaches using comprehensive heart-cut multidimensional gas chromatography (H/C MDGC) to experimentally investigate effects of concentration and temperature on peak shapes and on kinetic analysis of E/Z isomerisation of oximes which undergo various extents of interconversion on D and D separation columns. Different stationary phase combinations were investigated. An SLB-IL76 D column results in good separation of the isomers but with negligible interconversion (D).
View Article and Find Full Text PDFFood Chem
July 2018
Estonian University of Life Sciences, Institute of Veterinary Medicine and Animal Sciences, Chair of Food Science and Technology, Kreutzwaldi 56/5, EE51014 Tartu, Estonia.
Recent years have had an increased demand for goat milk and its products. The quality of goat milk is determined, in part, by the fatty acid (FA) profile, but there is little information about breed influence on the FA profile of goat milk. The aim of this study was to describe and compare FA profiles of goat milk produced by Saanen and Swedish Landrace breeds.
View Article and Find Full Text PDFJ Agric Food Chem
January 2018
Guelph Food Research Centre, Agriculture and Agri-Food Canada , Guelph N1G 5C9, Ontario, Canada.
Incubation of DHA with sheep rumen fluid resulted in 80% disappearance in 6 h. The products were analyzed as their fatty acid (FA) methyl esters by GC-FID on SP-2560 and SLB-IL111 columns. The GC-online reduction × GC and GC-MS techniques demonstrated that all DHA metabolites retained the C22 structure (no evidence of chain-shortening).
View Article and Find Full Text PDFAnal Bioanal Chem
July 2018
Department of Chemistry and Biochemistry, University of Texas at Arlington, 700 Planetarium place, Arlington, TX, 76019, USA.
Twelve bis- or dicationic ionic liquids (ILs) including eight based on imidazolium, a single one based on phosphonium, and three based on pyrrolidinium cationic units were prepared with the bis(trifluoromethyl sulfonyl) imide anion. The two identical cationic moieties were attached by different alkyl spacers having three or five carbons and differing alkyl substituents attached to the spacer. The SLB-IL111 column, as the most polar commercial stationary phase known, was included in the study for comparison.
View Article and Find Full Text PDFAnal Bioanal Chem
July 2018
Instituto de Química, Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, 21945-970, Brazil.
This study investigates applications and performance evaluation of SLB-IL60, SLB-IL76 and SLB-IL111 columns, in relation to a DB-Wax column, for the analysis of coffee volatile compounds. Both standards and an authentic coffee sample were analysed, with solid-phase microextraction (SPME) sampling of the latter. A cryofocusing method was applied to improve resolution of the earliest eluting peaks using splitless injection SPME sample analysis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!