Background: There are various regimens for thromboprophylaxis after hip replacement. Low-molecular-weight heparins such as enoxaparin predominantly inhibit factor Xa but also inhibit thrombin to some degree. Orally active, specific factor Xa inhibitors such as apixaban may provide effective thromboprophylaxis with a lower risk of bleeding and improved ease of use.
Methods: In this double-blind, double-dummy study, we randomly assigned 5407 patients undergoing total hip replacement to receive apixaban at a dose of 2.5 mg orally twice daily or enoxaparin at a dose of 40 mg subcutaneously every 24 hours. Apixaban therapy was initiated 12 to 24 hours after closure of the surgical wound; enoxaparin therapy was initiated 12 hours before surgery. Prophylaxis was continued for 35 days after surgery, followed by bilateral venographic studies. The primary efficacy outcome was the composite of asymptomatic or symptomatic deep-vein thrombosis, nonfatal pulmonary embolism, or death from any cause during the treatment period. Patients were followed for an additional 60 days after the last intended dose of study medication.
Results: A total of 1949 patients in the apixaban group (72.0%) and 1917 patients in the enoxaparin group (71.0%) could be evaluated for the primary efficacy analysis. The primary efficacy outcome occurred in 27 patients in the apixaban group (1.4%) and in 74 patients in the enoxaparin group (3.9%) (relative risk with apixaban, 0.36; 95% confidence interval [CI], 0.22 to 0.54; P<0.001 for both noninferiority and superiority; absolute risk reduction, 2.5 percentage points; 95% CI, 1.5 to 3.5). The composite outcome of major and clinically relevant nonmajor bleeding occurred in 129 of 2673 patients assigned to apixaban (4.8%) and 134 of 2659 assigned to enoxaparin (5.0%) (absolute difference in risk, -0.2 percentage points; 95% CI, -1.4 to 1.0).
Conclusions: Among patients undergoing hip replacement, thromboprophylaxis with apixaban, as compared with enoxaparin, was associated with lower rates of venous thromboembolism, without increased bleeding. (Funded by Bristol-Myers Squibb and Pfizer; ClinicalTrials.gov number, NCT00423319.).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1056/NEJMoa1006885 | DOI Listing |
Br J Hosp Med (Lond)
January 2025
Department of Osteoarthritis, Yantai City Yantai Shan Hospital, Yantai, Shandong, China.
Deep venous thrombosis (DVT) represents a significant postoperative complication after artificial femoral head replacement, with the incidence increasing proportionally with patient age. This study aimed to evaluate the effect of early postoperative use of intermittent pneumatic compression devices (IPC), followed by the combined use of low molecular weight heparin (LMWH) after 48 hours, for the prevention of postoperative lower limb DVT in elderly patients undergoing hip arthroplasty. The retrospective study included 100 elderly patients who underwent unilateral femoral head replacement.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopaedic Surgery, Chosun University Hospital, 365 Pilmundae-ro, Dong-gu, Gwangju 61453, Republic of Korea.
Managing periprosthetic femoral fractures is challenging, particularly in osteoporotic patients with fragile bones. Revision with a long stem is commonly considered but may fail to provide adequate fixation and stability in fragile bones. A novel approach using sandwiched strut allografts and controlled bone crushing with robust cable fixation can offer mechanical support and provide secondary stability to the loosened femoral stem and can be considered a treatment option for low-demand patients.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedics and Traumatology, Karabük University, Karabük 78050, Turkey.
The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Anesthesiology and Intensive Care, Astana Medical University, Astana 010000, Kazakhstan.
This case report highlights the use of continuous infusion of meropenem in a 42-year-old septic female patient with periprosthetic infection and end-stage renal disease receiving prolonged intermittent renal replacement therapy (PIRRT). Antibiotic infusion in patients receiving renal replacement therapy has its own peculiarities. There are many studies on the optimal dosing regimen for meropenem in renal dysfunction, but studies on the optimal infusion duration in these patients are limited.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Ankara Etlik City Hospital, Ankara, Turkey.
Background: Cementless hip hemiarthroplasty is one of the options for the treatment of osteoporotic femoral neck fractures. Intraoperative periprosthetic femoral calcar fractures sometimes occur during the surgery, and the use of cerclage wiring to maintain the position and stability of the femoral stem and prevent the progression of the fracture. This study examines the outcomes of cerclage wiring to treat intraoperative periprosthetic calcar fractures in cementless hip hemiarthroplasty in osteoporotic femoral neck fractures.