The objective of the present investigation is to develop and validate a simple, economical and reliable high performance liquid chromatography method for the quantification of quetiapine (CAS 111974-72-2) in human plasma with a quantification limit sufficiently low to support pharmacokinetic studies. Imipramine hydrochloride (CAS 113-52-0) was used as internal standard. The validated method allows quantification of quetiapine in 15-1000 ng/mL. The method was shown to be precise (< 7% coefficient of variation, CV) and accurate (< or = 10% relative error, RE). The correlation coefficient for quetiapine was > 0.9970. The simplicity of the assay and rapid liquid-liquid extraction make it an attractive procedure in high-throughput bioanalysis of quetiapine.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-0031-1296343 | DOI Listing |