A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection of diastolic potentials around the mitral annulus of structurally normal human hearts. | LitMetric

To examine the electrophysiologic characteristics of the subvalvular mitral region, we retrospectively searched for the presence of subvalvular diastolic potentials (DP) in 91 patients (mean age, 46.9 ± 16.6 years) who underwent catheter ablation of left-sided accessory pathways (AP). We detected low-amplitude (0.19 ± 0.09 mV) DP in 14 patients (15.4%), including 8 with overt preexcitation and 6 patients with concealed AP. The mean interval between ventricular electrogram and DP was 383 ± 46 ms (range, 306-475). DP were detected in 4 of 20 patients with antero-lateral, 3 of 38 with lateral, 4 of 12 with postero-lateral, 2 of 14 with posterior, and 3 of 10 patients with postero-septal AP. In 6 of 14 patients, DP were detected before ablation. In 4 of 8 patients with overt preexcitation, DP were consistently recorded after elimination of the delta wave, suggesting that they were not associated with AP conduction. In 6 of 11 patients, DP were observed during both sinus rhythm and ventricular pacing, suggesting that they were not artifacts. The electrophysiologic characteristics of clinically relevant DP around the mitral annulus suggest that, in normal human hearts, an anatomical substrate may be present around the mitral annulus.

Download full-text PDF

Source
http://dx.doi.org/10.1536/ihj.51.394DOI Listing

Publication Analysis

Top Keywords

mitral annulus
12
diastolic potentials
8
normal human
8
human hearts
8
electrophysiologic characteristics
8
patients
8
overt preexcitation
8
detection diastolic
4
mitral
4
potentials mitral
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!