10% Povidone-iodine may be a practical field water disinfectant.

Wilderness Environ Med

Department of Emergency Medicine, Madigan Army Medical Center, Tacoma, WA, USA.

Published: December 2010

Objective: A paucity of data exists regarding the use of iodophores such as povidone-iodine (PVI) to disinfect water. We sought to determine a practical minimal disinfecting concentration of 10% PVI over different contact times and temperatures when added to water inoculated with E. coli.

Methods: 1:100, 1:1,000, and 1:10,000 dilutions of 10% PVI were created. Escherichia coli was exposed to these dilutions for 5, 15, and 30 minutes at 10, 20, and 30°C. Bactericidal activity was neutralized with 0.5% sodium thiosulfate. Mean viable colony forming units (CFUs) was determined after triplicate plating on Luria-bertani agar and 24 hours of incubation at 37°C. Effective bactericidal activity was defined as a 5-log reduction.

Results: Of the 200,000 E. coli plated, no CFUs were observed after exposure to the 1:100 dilution. After 5 minutes of contact time with the 1:1,000 dilution, at 10°C CFUs were too numerous to count (TNTC), at 20°C the mean CFU count was 92 (standard error ±11), and at 30°C the mean CFU count was 25 (standard error ±8). No CFUs were observed after 15 minutes of exposure to the 1:1,000 dilution across experimental temperatures. The 1:10,000 dilution always yielded CFU growth that was TNTC.

Conclusions: The lowest disinfecting concentration of 10% PVI was the 1:1,000 dilution at 15 minutes of contact time. This supports the use of PVI for water disinfection against E. coli, the organism most commonly responsible for traveler's diarrhea. Further studies may assess its effectiveness against more virulent water borne pathogens.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wem.2010.09.008DOI Listing

Publication Analysis

Top Keywords

10% pvi
12
11000 dilution
12
disinfecting concentration
8
concentration 10%
8
bactericidal activity
8
cfus observed
8
dilution minutes
8
minutes contact
8
contact time
8
cfu count
8

Similar Publications

Background: Loss of bipolar electrograms immediately after pulsed field ablation (PFA) makes lesion durability assessment challenging.

Objective: The aim of this trial (NCT06700226) was to evaluate a novel ablation system that can optically predict lesion durability by detecting structural changes in the tissue during ablation.

Methods: Patients with paroxysmal atrial fibrillation underwent pulmonary vein isolation (PVI) using PFA (AblaView®, MedLumics).

View Article and Find Full Text PDF

Background: Use of pulmonary vein isolation (PVI) to treat atrial fibrillation continues to increase. Despite great interest in leveraging administrative data for real-world analyses, contemporary procedural codes for identifying PVI have not been evaluated.

Methods And Results: In this observational retrospective cohort study, inpatient PVIs were identified among US Medicare fee-for-service beneficiaries using Current Procedural Terminology (CPT) code 93656 in Carrier Line Files.

View Article and Find Full Text PDF
Article Synopsis
  • This study investigates the impact of two types of ablation (radiofrequency and cryoballoon) on the quality of life (QoL) in patients with paroxysmal atrial fibrillation (PAF).
  • Both RF and cryo procedures showed significant improvements in QoL metrics after 12 months, with sustained benefits at 30 months, indicating both methods are effective.
  • However, performing additional ablations did not result in further QoL enhancements compared to those who only underwent pulmonary vein isolation (PVI).
View Article and Find Full Text PDF

Background: Surgical site infections (SSI) following clean abdominal surgery in cattle pose significant economic and welfare concerns. Preoperative skin asepsis aims to minimize microbial load over the surgical field before and throughout surgery to minimize its risk. While chlorhexidine (CHX) and povidone-iodine (PVI) are commonly used antiseptics for this purpose, our study introduces the so far unexplored use of octenidine (OCT) in veterinary surgery.

View Article and Find Full Text PDF

Background: The optimal radiofrequency application (RFa) parameters for safe and durable pulmonary vein isolation (PVI) are debated. High-power short-duration (HPSD) has been used as an alternative to conventional power delivery (CPD).

Objectives: This study sought to compare HPSD 70 W/9-10 s (HPSD-70) with CPD 25-40 W in patients undergoing PVI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!