Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Vitamin D therapy is widely used for the treatment of hyperparathyroidism associated with chronic renal failure in renal disease patients. The vitamin D prodrug, 1α-hydroxyvitamin D(2) (1α(OH)D(2)), is used for the treatment of the end stage renal disease patients who as a result of impaired kidney function cannot convert the naturally occurring vitamin D to the active hormonal form namely 1,25-dihydroxyvitamin D(2) (1,25(OH)(2)D(2)). The systemic circulating levels of this active form are in the pg/mL range and represent a significant bioanalytical challenge for therapeutic monitoring. Liquid chromatography with tandem mass spectrometry (LC-MS/MS) is considered the gold standard for the selective and sensitive determination of small molecule therapeutics in biological matrices. However, the reported LC-MS/MS bioanalytical assays for 1,25(OH)(2)D(2) suffer from extensive sample preparation procedures or derivatization protocols to achieve the requisite sensitivity and selectivity. In this paper, we describe an assay that employs 96-well plate solid phase extraction sample preparation combined with highly sensitive LC-MS/MS instrumentation. The utility of ultra high pressure liquid chromatography to reduce the analytical run time was also demonstrated. Employing this assay a lower limit of quantitation of 25.0 pg/mL using 300 μL sample aliquot of rat serum was achieved with linearity obtained over the range of 25.0-1000 pg/mL. Both intra-day and inter-day coefficients of variation were <15% and accuracy across the assay range was within 100±7.24%. The application of the assay was demonstrated for the analysis of 1,25(OH)(2)D(2) rat serum samples to support pharmacokinetic studies conducted at doses down to sub-microgram per kilogram of 1α(OH)D(2).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2010.11.025 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!