Development and evaluation of a multiple-plate fraction collector for sample processing: application to radioprofiling in drug metabolism studies.

J Pharm Biomed Anal

Department of Biotransformation, Bristol-Myers Squibb, Route 206 and Province Line Road, Princeton, NJ 08543, USA.

Published: April 2011

Microplate scintillation counters are utilized routinely in drug metabolism laboratories for the off-line radioanalysis of fractions collected during HPLC radioprofiling. In this process, the current fraction collection technology is limited by the number of plates that can be used per injection as well as the potential for sample loss due to dripping or spraying as the fraction collector head moves from well to well or between plates. More importantly, sample throughput is limited in the conventional process, since the collection plates must be manually exchanged after each injection. The Collect PAL, an innovative multiple-plate fraction collector, was developed to address these deficiencies and improve overall sample throughput. It employs a zero-loss design and has sub-ambient temperature control. Operation of the system is completely controlled with software and up to 24 (96- or 384-well) fraction collection plates can be loaded in a completely automated run. The system may also be configured for collection into various-sized tubes or vials. At flow rates of 0.5 or 1.0 mL/min and at collection times of 10 or 15s, the system precisely delivered 83-μL fractions (within 4.1% CV) and 250-μL fractions (within 1.4% CV), respectively, of three different mobile phases into 12 mm × 32 mm vials. Similarly, at a flow rate of 1 mL/min and 10s collection times, the system precisely dispensed mobile phase containing a [(14)C]-radiolabeled compound across an entire 96-well plate (% CV was within 5.3%). Triplicate analyses of metabolism test samples containing [(14)C]buspirone and its metabolites, derived from three different matrices (plasma, urine and bile), indicated that the Collect PAL produced radioprofiles that were reproducible and comparable to the current technology; the % CV for 9 selected peaks in the radioprofiles generated with the Collect PAL were within 9.3%. Radioprofiles generated by collecting into 96- and 384-well plates were qualitatively comparable; however, the peak resolution was greater in the profiles that were collected in 384-well plates due to the collection of a larger number of fractions per minute. In conclusion, this new and innovative fraction collector generated radioprofile results that were comparable to current technology and should provide a major improvement in capacity and throughput for radioprofiling studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2010.11.029DOI Listing

Publication Analysis

Top Keywords

fraction collector
16
collect pal
12
multiple-plate fraction
8
drug metabolism
8
fraction collection
8
sample throughput
8
collection plates
8
96- 384-well
8
vials flow
8
collection times
8

Similar Publications

High-precision Cu isotopic analysis of human dietary Cu sources via multi-collector ICP-mass spectrometry.

Food Chem

December 2024

Atomic and Mass Spectrometry - A&MS Research Unit, Department of Chemistry, Ghent University, 9000 Ghent, Belgium. Electronic address:

The disruption of Cu homeostasis is associated with the pathogenesis of many diseases and can result in alterations in Cu isotope fractionation. Changes in the Cu isotope ratio (Cu/Cu) of body fluids and tissues have been observed in liver disorders, cancers, and other diseases, displaying diagnostic/prognostic potential. However, it is not entirely clear whether certain physiological or lifestyle factors may also influence the bodily Cu isotopic composition, potentially obfuscating the signature of the pathology.

View Article and Find Full Text PDF

High-performance liquid chromatography (HPLC) is an invaluable technique that has been used for many decades for the separation of various molecules. The reproducible collection of eluates from these systems has been significantly improved via its automation by fraction collection systems. Current commercially available fraction collectors are not easily customizable, incompatible with other platforms, and come with a large cost barrier making them inaccessible to many researchers.

View Article and Find Full Text PDF

The optimization of heat transfer in various engineering applications, such as thermal management systems and energy storage devices, remains a crucial challenge. This study aims to investigate the potential of Casson-based Cu-HO nanofluids in enhancing free convection heat transfer within complex geometries. The research examines the free convection heat transfer and fluid flow characteristics of a Casson-based Cu-HO nanofluid within a semi-parabolic enclosure that includes a wavy corrugated cylinder.

View Article and Find Full Text PDF

Deciphering the mineral code of urinary stones: A first look at zinc isotopes.

Environ Pollut

December 2024

Nu Instruments, Wrexham Industrial Estate, 74 Clywedog Road South, Wrexham, LL13 9XS, United Kingdom.

Zinc (Zn) is an essential element for all living organisms, and Zn isotopes play a key role in studying the formation of disease. Despite extensive studies on Zn isotopes in healthy and diseased human tissues, the role of Zn isotopes in urinary stones remains unexplored. This study investigates Zn isotopes in 37 urinary stones using multi-collector inductively coupled plasma mass spectrometry.

View Article and Find Full Text PDF

Diagnosis of atrial fibrillation as the source of cryptogenic retrieved clots by a novel thrombin secretion assay.

Heart Rhythm

December 2024

Department of Neurology, The Chaim Sheba Medical Center, Ramat Gan, Israel; Department of Neurology and Neurosurgery, Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel; The TELEM Rubin Excellence in Biomedical Research Program, The Chaim Sheba Medical Center, Ramat Gan, Israel. Electronic address:

Article Synopsis
  • The study focused on improving the diagnosis of clot sources in acute ischemic stroke, particularly distinguishing between atrial fibrillation (AF) and atherosclerosis (AS).
  • A new column-based assay for thrombin secretion was developed, which proved to be faster and more informative than previous methods.
  • The assay demonstrated high sensitivity and specificity, correctly identifying a significant percentage of patients with AF, thereby enhancing the understanding of cryptogenic strokes and their potential causes.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!