Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: intravenous administration of adenosine triphosphate (ATP) is used to induce transient pulmonary vein (PV) reconduction (dormant PV conduction) following PV isolation. This study investigated the detailed characteristics of dormant PV conduction in patients with atrial fibrillation (AF) who underwent catheter ablation.
Methods: two hundred sixty consecutive patients (235 men; mean age, 54 ± 10 years) who underwent catheter ablation of their AF were included in this study. ATP was injected following PV isolation to induce dormant PV conduction, which was then eliminated by radiofrequency application.
Results: dormant PV conduction was induced by ATP in 60.4% (157/260) of the patients and in 25.3% (258/1,021) of the isolated PVs. This transient PV reconduction was more frequently observed in the left superior PV in comparison with other PVs (P < .0001). There was no significant difference in the prevalence of the dormant PV conduction among patients with paroxysmal AF, persistent AF, and long-lasting AF (62%, 66%, and 48%, respectively; P = .13). During the follow-up period, repeat AF ablation was performed in 70 patients with recurrent AF. The dormant PV conduction was less frequently induced in the repeat procedure than in the initial procedure (60.4% vs 31.4%, P < .0001).
Conclusions: dormant PV conduction was evenly induced among AF types. The repeat PV isolation led to the decrease in incidence of the ATP-induced acute transient pharmacological PV reconduction.