Statement Of Problem: Macroscopic and especially microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Dental implants with modified surfaces have shown stronger osseointegration than implants which are only turned (machined). Advanced surface modification techniques such as anodic oxidation and Ca-P application have been developed to achieve faster and stronger bonding between the host bone and the implant.
Purpose: The purpose of this study was to investigate the effect of surface treatment of titanium dental implant on implant stability after insertion using the rabbit tibia model.
Material And Methods: THREE TEST GROUPS WERE PREPARED: sandblasted, large-grit and acid-etched (SLA) implants, anodic oxidized implants, and anodized implants with Ca-P immersion. The turned implants served as control. Twenty rabbits received 80 implants in the tibia. Resonance frequencies were measured at the time of implant insertion, 2 weeks and 4 weeks of healing. Removal torque values (RTV) were measured 2 and 4 weeks after insertion.
Results: The implant stability quotient (ISQ) values of implants for resonance frequency analysis (RFA) increased significantly (P < .05) during 2 weeks of healing period although there were no significant differences among the test and control groups (P > .05). The test and control implants also showed significantly higher ISQ values during 4 weeks of healing period (P < .05). No significant differences, however, were found among all the groups. All the groups showed no significant differences in ISQ values between 2 and 4 weeks after implant insertion (P > .05). The SLA, anodized and Ca-P immersed implants showed higher RTVs at 2 and 4 weeks of healing than the machined one (P < .05). However, there was no significant difference among the experimental groups.
Conclusion: The surface-modified implants appear to provide superior implant stability to the turned one. Under the limitation of this study, however, we suggest that neither anodic oxidation nor Ca-P immersion techniques have any advantage over the conventional SLA technique with respect to implant stability.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2994679 | PMC |
http://dx.doi.org/10.4047/jap.2009.1.2.107 | DOI Listing |
Psychiatr Pol
October 2024
Śląskie Centrum Chorób Serca w Zabrzu; Katedra i Klinika Kardiochirurgii, Transplantologii, Chirurgii Naczyniowej i Endowaskularnej, Wydział Nauk Medycznych w Zabrzu, SUM w Katowicach.
During qualification for mechanical circulatory support, the comprehensive assessment of a patient's mental state is an integral element of the overall medical evaluation. It encompasses a range of psychosocial issues, and as such provides information helpful in the selection of a suitable candidate for the required treatment, and sometimes identifies contraindications to it. It allows ensuring that the patient meets expectations regarding both mental health stability and adherence to medical recommendations.
View Article and Find Full Text PDFBMC Oral Health
January 2025
State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases & Department of Implant Dentistry, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China.
Purpose: This study aimed to evaluate the osteogenic performance of allograft particulate bone and cortical bone blocks combined with xenograft under bovine pericardium membranes, for treating different degrees of labial bone defects in the aesthetic zone.
Materials And Methods: Twenty-four patients with bone defects were divided into two groups based on defect severity (Terheyden 1/4 and 2/4 groups). The Terheyden 1/4 group received granular bone grafts alone, while the Terheyden 2/4 group received cortical bone blocks combined with granular bone grafts.
Am J Cardiol
January 2025
Department of Cardiovascular Medicine, Osaka University Graduate School of Medicine, Suita, Japan.
A dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo Stent (DTS) has been developed to enhance endothelization and capture endothelial progenitor cells; however, vessel responses following DTS implantation remain unclear. Therefore, we evaluated early- and mid-term intravascular characteristics of DTS using intravascular imaging modalities. This multicenter, prospective, observational study enrolled 88 patients (95 lesions) who underwent DTS (43 patients, 48 lesions) or sirolimus-eluting Orsiro stent (SES, 45 patients, 47 lesions) implantation.
View Article and Find Full Text PDFJ Plast Reconstr Aesthet Surg
January 2025
Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seongnam, South Korea. Electronic address:
Background: Type II lunate has an extra facet with the hamate. This difference alters the biomechanics of the midcarpal joint, influencing the development of scapho-trapezio-trapezoid (STT) arthritis. We aimed to investigate whether, in patients with trapeziometacarpal (TMC) osteoarthritis (OA), involvement of the STT joint is associated with the lunate type.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
January 2025
School of Materials Science and Engineering, University of Jinan, Jinan, 250022, China. Electronic address:
Silicon nitride (Si₃N₄) ceramics exhibit excellent mechanical properties and biocompatibility, making them highly suitable for biomedical applications, particularly in implants. In this study, the mechanical properties and bioactivity of Si₃N₄ ceramics with varying amounts of Y₂O₃-Al₂O₃-SiO₂ sintering aids were investigated. Increasing the sintering additive content from 4 wt% to 8 wt% substantially improved the bulk density of the ceramics, leading to notable enhancements in mechanical properties.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!