Optical interference filters utilizing tunable refractive index layers are shown to have higher spectral fidelity as compared to conventional filters consisting of non-tunable refractive index layers. To demonstrate this increase in spectral fidelity, we design and compare a variety of optical interference filters employing both tunable and non-tunable refractive index layers. Additionally, a five-layer optical interference filter utilizing tunable refractive index layers is designed and fabricated for use with a Xenon lamp to replicate the Air Mass 0 solar irradiance spectrum and is shown to have excellent spectral fidelity.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.18.00A594DOI Listing

Publication Analysis

Top Keywords

refractive layers
20
optical interference
16
interference filters
12
utilizing tunable
12
tunable refractive
12
spectral fidelity
12
filters utilizing
8
non-tunable refractive
8
refractive
5
layers
5

Similar Publications

High-refractive-index (HRI) dielectrics are gaining increasing attention as building blocks for compact lasers. Their ability to simultaneously support both electric and magnetic modes provides greater versatility as compared to plasmonic platforms. Moreover, their reduced absorption loss minimizes heat generation, further enhancing their performance.

View Article and Find Full Text PDF

Background: Glaucoma, particularly open-angle glaucoma (OAG), is a leading cause of irreversible blindness, associated with optic nerve damage, retinal ganglion cell death, and visual field defects. Corneal biomechanical properties and cellular components, such as corneal nerve and keratocyte densities assessed by in vivo confocal microscopy (IVCM), may serve as biomarkers for glaucoma progression. This study aimed to explore the relationship between corneal nerve parameters, keratocyte density, and optical coherence tomography (OCT)-derived retinal nerve fiber layer (RNFL) thickness in primary open-angle glaucoma (POAG) patients and controls.

View Article and Find Full Text PDF

To report the cosmetic, clinical, and visual outcomes of a combined surgical approach for treating a corneal/limbal dermoid using excision and a three-layered amniotic membrane graft with fibrin glue. An 18-year-old female presented with impaired vision and ocular discomfort caused by a prominent dome-shaped limbal congenital dermoid on the inferotemporal cornea, resulting in a significant aesthetic concern. A full assessment, including refraction, best-corrected visual acuity (BCVA), corneal topography, aberrometry and anterior segment OCT (AS-OCT) was conducted to plan the surgical approach.

View Article and Find Full Text PDF

SPR Biosensor Based on Bilayer MoS for SARS-CoV-2 Sensing.

Biosensors (Basel)

January 2025

INFN-Laboratori Nazionali di Frascati, Via E. Fermi 54, 00044 Frascati, Italy.

The COVID-19 pandemic has highlighted the urgent need for rapid, sensitive, and reliable diagnostic tools for detecting SARS-CoV-2. In this study, we developed and optimized a surface plasmon resonance (SPR) biosensor incorporating advanced materials to enhance its sensitivity and specificity. Key parameters, including the thickness of the silver layer, silicon nitride dielectric layer, molybdenum disulfide (MoS) layers, and ssDNA recognition layer, were systematically optimized to achieve the best balance between sensitivity, resolution, and attenuation.

View Article and Find Full Text PDF

Purpose: Chemical chelation with ethylenediaminetetraacetic acid (EDTA) is an established treatment for calcific band keratopathy (CBK), whereas removal of calcium deposits from the subepithelial layer of the cornea may cause corneal irregularity. Using Fourier harmonic analysis, we analyzed the corneal topography in eyes with CBK treated by EDTA chelation.

Study Design: Retrospective, single-center study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!