Background: Renal failure is a frequent complication of juxtarenal abdominal aortic aneurysm (JAA)-repair. During this operation, suprarenal aortic-clamping is followed by infrarenal aortic-clamping (below renal arteries) to restore renal flow, while performing the distal anastomosis. We hypothesized that infrarenal aortic-clamping, despite restoring renal perfusion provokes additional renal damage.

Materials And Methods: We studied three groups of rats. After 45min of suprarenal aortic-clamping, group 1 had renal reperfusion for 90min without aortic-clamps (n=7). In group 2, 45min of suprarenal aortic-clamping with a distal clamp on the aortic-bifurcation was followed by 20min of infrarenal aortic-clamping. Renal reperfusion was continued for 70min without aortic-clamps (i.e. 90 min of renal reperfusion; n=8). The sham-group had no clamps (n=7). We measured renal haemodynamics, functional parameters and tissue damage.

Results: On suprarenal aortic-clamp removal, renal artery flow, cortical flow and arterial pressures were higher in group 2 than in group 1. We detected increased tubular brush border damage, luminal lipocalin-2 and 30-60% higher renal protein nitrosylation in group 2 when compared to group 1 (P<0·05). Group 2 showed more release of asymmetrical dimethylarginine (ADMA) from the kidneys in the renal vein, therefore indicating diminished clearing capacity (P<0·001). Arginine/ADMA-ratio, which defines the bio-availability of nitric oxide, tended to be lower in group 2 and correlated with renal flow. Furthermore, there were no significant differences found in creatinine levels and renal leucocyte accumulation between group 1 and 2.

Conclusions: Additional infrarenal aortic-clamping leads to increased renal damage and oxidative stress, despite adequate perfusion of kidneys after suprarenal aortic-clamping. This study indicates that the clamping sequence used in JAA-repair causes more than simple renal I/R-injury.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2362.2010.02448.xDOI Listing

Publication Analysis

Top Keywords

infrarenal aortic-clamping
16
renal
13
aortic-clamping renal
12
suprarenal aortic-clamping
12
renal reperfusion
12
renal failure
8
45min suprarenal
8
aortic-clamping
6
group
6
infrarenal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!