We assessed polyethylene wear and osteolysis in 15 patients (30 hips) undergoing staged bilateral total hip arthroplasties, who had a cemented arthroplasty on one side and a hybrid arthroplasty on the other. All factors apart from mode of acetabular component fixation were matched. Wear was measured radiographically using Livermore's technique. The mean clinical and radiological follow-up was 11.2 years for the cemented and 10.7 years for the hybrid arthroplasties. Mean annual linear wear rate was 0.09mm/year in the cemented sockets and 0.14mm/year in the uncemented sockets. This difference was statistically significant (p=0.03), confirming previous reports that the rate of polyethylene wear is increased in uncemented sockets. No periacetabular osteolysis was noted. Femoral osteolysis in zone 7 occurred in 3 hybrid arthroplasties. It appears not all patients are equally affected. These results are further discussed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/112070001002000406 | DOI Listing |
J Orthop Surg Res
January 2025
Department of Orthopaedics, Liaocheng People's Hospital, Liaocheng, Shandong, P.R. China.
Background: Vitamin E-diffused highly cross-linked polyethylene (HXLPE/Vit E) is a relatively advanced material used in total hip arthroplasty (THA) but whether it shows superiority is unclear.
Objective: This meta-analysis was performed to investigate the effect of HXLPE/Vit E liners in THA.
Methods: Medline/PubMed, Embase and Cochrane Library databases were searched to retrieve studies assessing the efficacy of HXLPE/Vit E liners in THA with the design of a randomized, controlled trial.
Environ Res
January 2025
Southern California Coastal Water Research Project, Costa Mesa, CA, 92626, United States.
The concentration, character, and distribution of microplastics in coastal marine environments remain poorly understood, with most research focusing on the abundance of microplastics at the sea surface. To address this gap, we conducted one of the first comprehensive assessments of microplastic distribution through the marine water column and benthic sediment during the wet and dry season in the coastal waters of the San Pedro Bay Southern California, USA. Microplastic concentrations in the water column did not vary significantly across season but were significantly higher in nearshore environments and at the surface of the water column.
View Article and Find Full Text PDFArthroplast Today
December 2024
Hospital Pavia Arecibo, Arecibo Orthopedic Institute, Arecibo, PR, USA.
Synovial fistula of the knee occurs when a defect in the joint capsule creates a connection between skin, bursa, and a near tissue, manifesting as an opening with continuous draining fluid or a cyst. This is a case of an 80-year-old male who developed a synovial fistula with cystic presentation 6 years after the primary total knee arthroplasty. Management included a total knee arthroplasty revision surgery with intraoperative identification of the fistula with methylene blue, and using a gelatin-thrombin matrix for closure.
View Article and Find Full Text PDFSurg Technol Int
January 2025
JIS Orthopedics Inc., New Albany, Ohio.
Accurate acetabular component positioning is crucial for the success of total hip arthroplasty (THA). Malplacement of the acetabular component increases the risk of post-surgery complications, most notably dislocation.1 Furthermore, malposition can also result in wear of the polyethylene liner, limited range of motion, and osteolysis.
View Article and Find Full Text PDFCureus
December 2024
Medical Affairs, Dr. Reddy's Laboratories Ltd., Hyderabad, IND.
Background Toothbrush manufacturers commonly use bristle materials such as nylon, polybutylene terephthalate, polypropylene, polyethylene terephthalate, boar hair, bamboo, carbon fiber, silicone, polylactic acid, or their modifications such as Curen. Nylon filaments have long been demonstrated to be durable and are widely used, but not much is known regarding the performance of Curen filaments compared to nylon filaments. This in vitro study compared the stiffness, abrasion potential, abrasion resistance, and bristle surface changes of Curen and nylon filaments.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!