A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraocular lens exchange through a 3.2-mm corneal incision for opacified intraocular lenses. | LitMetric

Intraocular lens exchange through a 3.2-mm corneal incision for opacified intraocular lenses.

Indian J Ophthalmol

Kartal Dr. Lütfi Kirdar Training and Research Hospital, 2nd Eye Clinic, Cevizli, Istanbul, Turkey.

Published: April 2011

Aim: The aim was to evaluate visual and refractive results and complications of intraocular lens (IOL) exchange through a 3.2 mm corneal incision for opacified IOLs.

Materials And Methods: This retrospective study comprised 33 eyes of 32 patients with IOL opacification requiring an IOL exchange between July 2003 and March 2007. Exchange surgery was performed through a 3.2-mm temporal clear corneal incision followed by implantation of a new foldable hydrophobic IOL. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), topographical astigmatism, and refractive cylinder were evaluated. Surgically induced astigmatism (SIA) was calculated and complications were recorded.

Results: Opacification was observed in 25 eyes (76%) with Aqua-Sense, 3 eyes (9%) with Hydroview, 3 eyes (9%) with MemoryLens IOLs, and 2 eyes (6%) with DgR. The mean follow-up period was 36.54 months. An uneventful IOL exchange was achieved in 18 eyes (55%). Zonular dehiscence occurred in 9 eyes (27%), and posterior capsule tear developed in 4 eyes (12%). The mean preoperative BSCVA (mean ± standard deviation, decimal scale) was 0.13 ± 0.08 (mean: 20/150, range 20/2000 to 20/60) and improved to 0.63 ± 0.18 (mean: 20/32, range 20/60 to 20/20, P < 0.001). The mean SIA was 0.70 D. Seven eyes (21%) had 0.5 D or lower SIA.

Conclusion: IOL exchange is a technically challenging procedure with potential risks of reversing the advantages of a prior small-incision cataract surgery. The use of a small corneal incision for IOL exchange could preserve the advantages of modern phacoemulsification surgery with acceptable SIA related to the procedure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3032237PMC
http://dx.doi.org/10.4103/0301-4738.73713DOI Listing

Publication Analysis

Top Keywords

iol exchange
20
corneal incision
16
eyes
9
intraocular lens
8
incision opacified
8
visual acuity
8
exchange
7
iol
7
lens exchange
4
exchange 32-mm
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!