A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dimensions of the foveal avascular zone using the Heidelberg retinal angiogram-2 in normal eyes. | LitMetric

Purpose: The purpose was to study the dimensions of the foveal avascular zone (FAZ) using Heidelberg Retinal Angiogram-2 (HRA-2; Heidelberg Engineering GmBH, Dossenheim, Germany).

Materials And Methods: An observational study of the FAZ area and circumference was done with fundus fluorescein angiography (FFA) using HRA-2 in 31 normal individuals. The FAZ was studied using both contrast-adjusted and nonadjusted methods. Contrast adjustment was done to obtain better visualization of the finer capillaries around the fovea enabling more precise measurements of the FAZ in normal eyes.

Results: The mean area of the FAZ calculated by the contrast-adjusted method was 0.2753 mm 2 (±0.074) and the mean circumference was 2.22 mm (±0.048). By the conventional method, the area and circumference of the FAZ were 0.6241 mm 2 (±0.177) and 3.23 mm (±0.454), respectively.

Conclusion: The measurements of area and circumference of FAZ using contrast-adjusted methods were significantly smaller than the conventional method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3032258PMC
http://dx.doi.org/10.4103/0301-4738.73706DOI Listing

Publication Analysis

Top Keywords

area circumference
12
dimensions foveal
8
foveal avascular
8
avascular zone
8
heidelberg retinal
8
retinal angiogram-2
8
conventional method
8
circumference faz
8
faz
7
zone heidelberg
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!