A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of a new homogenous method for detection of small dense LDL cholesterol: comparison with the LDL cholesterol profile obtained by density gradient ultracentrifugation. | LitMetric

Background: Small, dense LDL (sdLDL) are highly atherogenic, and evidence indicates that sdLDL are useful predictors of cardiovascular disease. We evaluated a homogeneous method for the quantitative determination of sdLDL cholesterol (sdLDL-C) and compared it to the LDL-cholesterol profile obtained by density gradient ultracentrifugation (DGUC).

Methods: sdLDL-C was measured in plasma and in lipoprotein fractions obtained by DGUC using the sdLDL-EX "Seiken" kit.

Results: sdLDL-C was only present in dense or intermediate LDL fractions obtained by DGUC. Plasma sdLDL-C levels were inversely corelated to the LDL relative floatation rate. The proportion of LDL-C that is sdLDL-C increases as a function of LDL density from a median of 19% for very buoyant LDL to 91% for very dense LDL particles. Plasma sdLDL-C level was significantly correlated with plasma triglyceride (TG) (n=840, r(s)=0.710, p<0.001). Among subjects with plasma TG>150 mg/dl, 75% had sdLDL-C>30 mg/dl, whereas among those with TG ≤ 150 mg/dl, only 17% had sdLDL-C>30 mg/dl.

Conclusions: This precise and fully automated method for measuring plasma levels of sdLDL-C will allow the analysis of large number of samples in routine laboratories which will facilitate the evaluation of the clinical usefulness of sdLDL as a risk factor for CHD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2010.12.003DOI Listing

Publication Analysis

Top Keywords

dense ldl
12
small dense
8
ldl
8
ldl cholesterol
8
profile density
8
density gradient
8
gradient ultracentrifugation
8
fractions dguc
8
plasma sdldl-c
8
sdldl-c
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!