The doubly labeled water method provides an objective and accurate measure of total energy expenditure in free-living subjects and is considered the gold-standard method for this measurement. Its use, however, is limited by the need to employ isotope ratio mass spectrometry (IRMS) to obtain the high-precision isotopic abundance analyses needed to optimize the dose of expensive (18) O-labeled water. Recently, cavity-ring down spectroscopy (CRDS) instruments have become commercially available and may serve as a less expensive alternative to IRMS. We compared the precision and accuracy of CRDS with those of IRMS for the measurement of total energy expenditure from urine specimens in 14 human subjects. The relative accuracy and precision (SD) for total body water was 0.5 ± 1% and for total energy expenditure was 0.5 ± 6%. The CRDS instrument displayed a memory between successive specimens of 5% for (18) O and 9% for (2) H. The memory necessitated carefully ordering of specimens to reduce isotopic disparity, performance of several injections of each specimen to condition the analyzer, and use of a mathematical memory correction on subsequent injections. These limited the specimen throughput to about one urine specimen per hour. CRDS provided accuracy and precision for isotope abundance measurements of urine that were comparable with those of IRMS. The memory problems were easily recognized by our experienced laboratory staff, but future efforts should be aimed at reducing the memory of the CRDS so that it would be less likely to result in poor reproducibility in laboratories using doubly labeled water for the first time.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.4795DOI Listing

Publication Analysis

Top Keywords

doubly labeled
12
labeled water
12
total energy
12
energy expenditure
12
accuracy precision
8
water
5
crds
5
memory
5
water analysis
4
analysis cavity
4

Similar Publications

Nutritional epidemiology aims to link dietary exposures to chronic disease, but the instruments for evaluating dietary intake are inaccurate. One way to identify unreliable data and the sources of errors is to compare estimated intakes with the total energy expenditure (TEE). In this study, we used the International Atomic Energy Agency Doubly Labeled Water Database to derive a predictive equation for TEE using 6,497 measures of TEE in individuals aged 4 to 96 years.

View Article and Find Full Text PDF

Use of Biotin-Labeled Geranyl Pyrophosphate for Analysis of Ykt6 Geranylgeranylation.

Methods Mol Biol

January 2025

Department of Molecular and Cellular Biology, Institute of Development, Aging and Cancer, Tohoku University, Sendai, Japan.

Functionally derivatized analogs of prenyl lipids are valuable tools for the detection and analysis of prenylated proteins. Using a biotinylated analog of geranylgeranyl, we previously identified Ykt6 as a substrate for a novel protein prenyltransferase, termed geranylgeranyltransferase type III (GGTase-III). Ykt6 is an evolutionarily highly conserved SNARE protein that regulates multiple intracellular trafficking pathways, including intra-Golgi trafficking and autophagosome-lysosome fusion.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigated how insulin sensitivity, insulin response to glucose, and diet affect fat loss and energy expenditure in African American women with obesity.
  • 69 women were assigned to either a low-fat or low-carbohydrate diet for 10 weeks, with measures of body composition and energy expenditure taken before and after.
  • Results showed that those on a low-CHO diet lost more fat and experienced less decline in energy expenditure than those on a low-fat diet, suggesting low-CHO diets may be more effective for fat loss in this group.
View Article and Find Full Text PDF

Rapid detection of SARS-CoV-2 RNA using a one-step fast multiplex RT-PCR coupled to lateral flow immunoassay.

BMC Infect Dis

December 2024

Laboratory of Molecular Epidemiology and Experimental Pathology, LR16IPT04, Institut Pasteur de Tunis, University of Tunis El Manar, Tunis, LR16IPT04, Tunisia.

Background: The COVID-19 has put emphasis on pivotal needs for diagnosis and surveillance worldwide, with the subsequent shortage of diagnostic reagents and kits. Therefore, it has become strategic for the countries to access diagnostics, expand testing capacity, and develop their own diagnostic capabilities and alternative rapid accurate nucleic acid diagnostics that are at lower costs. Here, we propose a visual SARS-CoV-2 detection using a one-step fast multiplex reverse transcription-PCR (RT-PCR) amplification coupled to lateral flow immunoassay detection on a PCRD device (Abingdon Health, UK).

View Article and Find Full Text PDF

Determination of microcystins and nodularins in ambient freshwater and seawater by liquid chromatography-mass spectrometry including toxin screening and identification.

Anal Chim Acta

January 2025

HAB Monitoring & Reference Branch, Stressor Detection and Impacts Division, National Centers for Coastal Ocean Science, NOAA National Ocean Service, 331 Fort Johnson Road, Charleston, SC, 29412, USA.

Background: Microcystins (MCs) and nodularins (NODs) produced by cyanobacteria occur in ambient freshwaters and across the freshwater-marine continuum, and pose health threats through drinking and recreational waters, as well as food resources. Approximately 300 MC and NOD toxins have been published, but less than 15 of them are commercially available as toxin standards. Our aim herein was to rapidly identify and quantify all toxin congeners, including those without standards, in water samples even at low abundance by reversed-phase solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) to provide insights into toxin levels and potential toxicity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!