Aims: To compare the acute and the 6 month outcome of catheter ablation of atrial fibrillation (AF) using irrigated tip magnetic catheter and remote magnetic cathter navigation (RMN) with manual catheter navigation (MCN) in patients with paroxysmal and persistent AF.

Methods And Results: In this retrospective analysis 356 patients (235 male, mean age: 57.9 ± 10.9 years) with AF (70.5%, paroxysmal) who underwent catheter ablation between August 2007 and May 2008 using either RMN (n = 70, 46 male, mean age: 57.9 ± 10.1 years, 50% paroxysmal) or MCN (n = 286, 189 male, mean age: 58.0 ± 13.9 years, 75.5% paroxysmal) were included. All patients completed an intensive follow-up strategy. Complete pulmonary vein isolation was achieved in 87.6 and 99.6% of patients in RMN and MCN groups, respectively (P < 0.05). The procedure, fluoroscopy, and radiofrequency application times were 223 ± 44 vs. 166 ± 52 min (P < 0.0001), 13.7 ± 7.8 vs. 34.5 ± 15.1 min (P < 0.0001), and 75.4 ± 20.9 vs. 53.2 ± 21.4 min (P < 0.0001) in RMN and MCN groups, respectively. Seven (10.0%) and 28 (9.8%) patients in RMN and MCN groups received antiarrhythmic medications during the follow-up (P = 0.96). All the patients completed the 6 month follow-up. Freedom from AF at 6 months was achieved in 57.8 and 66.4% of the patients in RMN and MCN groups, respectively (P = 0.196). In patients without previous AF catheter ablation procedure the freedom from AF at 6 months were 68.2 and 60.5% in the MCN and RMN groups, respectively (P = 0.36).

Conclusion: Catheter ablation using irrigated tip magnetic catheter and RMN is an effective and safe method for catheter ablation of AF. Compared to manual catheter navigation, the procedure and radiofrequency application times were longer and fluoroscopy time was shorter in the RMN group compared with the MCN group.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/euq344DOI Listing

Publication Analysis

Top Keywords

catheter ablation
24
rmn mcn
16
mcn groups
16
magnetic catheter
12
catheter navigation
12
male age
12
patients rmn
12
min 00001
12
catheter
11
rmn
9

Similar Publications

A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation.

J Cardiothorac Surg

January 2025

Department of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian Clinical Medical Research Center for Heart and Macrovascular Disease, Fuzhou, 350001, China.

Objective: The objective of this study is to assess the predictive utility of perioperative P-wave parameters in patients with paroxysmal atrial fibrillation (PAF) undergoing catheter ablation, and to develop a predictive model using these parameters.

Methods: A total of 213 patients with PAF undergoing catheter ablation were retrospectively analyzed. P-wave parameters were measured within 3 days preoperatively and on the day postoperatively to determine their predictive significance for postoperative PAF recurrence.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF) is the most prevalent arrhythmia encountered in clinical practice. Triglyceride glucose index (Tyg), a convenient evaluation variable for insulin resistance, has shown associations with adverse cardiovascular outcomes. However, studies on the Tyg index's predictive value for adverse prognosis in patients with AF without diabetes are lacking.

View Article and Find Full Text PDF

This study aims to improve the quality of clinical treatment and nursing care to standardize perioperative management for patients with liver tumors undergoing co-ablation system therapy. The Committee of Ablation Therapy in Oncology, China Anti-Cancer Association; the Expert Committee on Ablation Therapy; Chinese Society of Clinical Oncology (CSCO); and the Committee of Interventional, Perioperative, and Interventional Physician Branch of Chinese Medical Doctors Association organized medical and nursing experts in China. Based on the clinical practice of co-ablation system therapy in China and relevant domestic literature, an expert consensus about perioperative management was developed.

View Article and Find Full Text PDF

Introduction: Electrophysiologic (EP) procedures are typically performed via the femoral venous system, but in some patients, the inferior vena cava (IVC) is unavailable. The hepatic vein has emerged as a viable alternative to femoral access, providing an inferior route that accommodates large sheaths required for better catheter manipulation. Although the percutaneous transhepatic approach has been used successfully in the pediatric population, its use in adults is scarce, with a complication rate of approximately 5%.

View Article and Find Full Text PDF

Introduction: Suture-mediated vascular closure devices have been widely used in catheter ablation, with 0.14-0.3 % incidence of pseudoaneurysm complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!