Filter light attenuation as a surrogate for elemental carbon.

J Air Waste Manag Assoc

Division of Atmospheric Sciences, Desert Research Institute, Reno, NV 89512, USA.

Published: November 2010

Light attenuation (b(att)) measured from filter light transmission is compared with elemental carbon (EC) measurements for more than 180,000 collocated PM2.5 (particulate matter [PM] < or = 2.5 microm in aerodynamic diameter) and PM10 (PM < or = 10 microm in aerodynamic diameter) samples from nearly 200 U.S. locations during the past 2 decades. Although there are theoretical reasons for expecting highly variable relationships between b(att) and EC (such as the effects of "brown carbon" and iron oxides in PM2.5), reasonable correlations are found. These correlations are not a strong function of season or location (e.g., rural vs. urban). Median EC concentrations can be predicted from filter transmittance measurements to within +/- 15-30%. Although EC predicted from b(att) shows larger uncertainties (30-60%), especially at concentrations less than 0.3 microg/m3, the consistent mass absorption efficiency (sigm(att)) derived from the regression analysis demonstrates the feasibility of using b(att) as a surrogate for EC. This study demonstrates that a constant factor of 0.1 g/m2 (equivalent to the 10 m2/g sigma(att) used in the Interagency Monitoring of Protected Visual Environments chemical extinction formula) can be used to estimate EC concentrations from b(att) through a Teflon-membrane filter sample. Greater accuracy is achieved with site-specific sigma(att) derived from a period with collocated EC measurements.

Download full-text PDF

Source
http://dx.doi.org/10.3155/1047-3289.60.11.1365DOI Listing

Publication Analysis

Top Keywords

filter light
8
light attenuation
8
elemental carbon
8
microm aerodynamic
8
aerodynamic diameter
8
batt
5
filter
4
attenuation surrogate
4
surrogate elemental
4
carbon light
4

Similar Publications

Background: Acute pain management is critical in postoperative care, especially in vulnerable patient populations that may be unable to self-report pain levels effectively. Current methods of pain assessment often rely on subjective patient reports or behavioral pain observation tools, which can lead to inconsistencies in pain management. Multimodal pain assessment, integrating physiological and behavioral data, presents an opportunity to create more objective and accurate pain measurement systems.

View Article and Find Full Text PDF

Void spot assay (VSA) noninvasively evaluates urination. VSA is often not performed in rats due to difficulty analyzing larger papers compared with mouse. This study optimizes VSA for rats by comparing post-assay visualization techniques: bright field light (BF), ultraviolet light (UV), and ninhydrin spray (N).

View Article and Find Full Text PDF

Vertical flow immunoassay for multiplex mycotoxins based on photonic nitrocellulose and SERS nanotags.

Food Chem X

January 2025

State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China.

Here, we report a SERS based VFA using PNC as a sensing substrate for highly sensitive multiplex mycotoxins detection. The PNC was fabricated by filtration-based self-assembled monodisperse SiO NPs on a filter membrane as a template, and the obtained PNC had an ordered complementary inverse opal structure. In parallel, three kinds of Raman dyes encoding Au@Ag, Au@Ag and Au@Ag SERS nanotags were synthesized for the detection of OTA, AFB1 and ZON.

View Article and Find Full Text PDF

Fluorescent iron nanoclusters are emerging fluorescent nanomaterials. Herein, we synthesized hemoglobin-coated iron nanoclusters (Hb-Fe NCs) with a significant fluorescence emission peak at 615 nm and investigated the inner-filter effect of fluorescence induced by a manganese dioxide nanosheet (MnO NS). The fluorescence quenching of Hb-Fe NCs by a MnO NS can be significantly reversed by the addition of ascorbic acid.

View Article and Find Full Text PDF

To enhance the positioning accuracy of autonomous underwater vehicles (AUVs), a new adaptive filtering algorithm (RHAUKF) is proposed. The most widely used filtering algorithm is the traditional Unscented Kalman Filter or the Adaptive Robust UKF (ARUKF). Excessive noise interference may cause a decrease in filtering accuracy and is highly likely to result in divergence by means of the traditional Unscented Kalman Filter, resulting in an increase in uncertainty factors during submersible mission execution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!