Nonenzymatic glucose sensor based on over-oxidized polypyrrole modified Pd/Si microchannel plate electrode.

Biosens Bioelectron

Laboratory of Polar Materials and Devices, Ministry of Education, and Department of Electronic Engineering, East China Normal University, Shanghai 200241, China.

Published: January 2011

A silicon microchannel plate (MCP) array electrode modified with over-oxidized polypyrrole (OPPy) has been fabricated to detect glucose. The morphology and structure of the electrode are characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The OPPy modified silicon MCP array electrode exhibits high electrocatalytic activity as well as excellent selectivity to the electrochemical oxidation of glucose. At a potential of +0.08 V, good sensitivity of 0.37 mA mM(-1) cm(-2) and detection limit of 2.06 μM are attained. The linear range is up to 24 mM with a linear correlation coefficient of 0.997. Furthermore, the electrode is highly resistant to interfering substances because the effects of common coexisting substances can be effectively eliminated by the OPPy film and the response in the current to interferences on the electrode surface is almost negligible. This novel electrode has high potential in nonenzymatic detection of glucose.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2010.11.010DOI Listing

Publication Analysis

Top Keywords

over-oxidized polypyrrole
8
microchannel plate
8
mcp array
8
array electrode
8
electrode
7
nonenzymatic glucose
4
glucose sensor
4
sensor based
4
based over-oxidized
4
polypyrrole modified
4

Similar Publications

Vesicular exocytosis is ubiquitous, but it is difficult to detect within the cells' communication mechanism. For this purpose, a 2 µm ultramicrodic carbon fiber electrode was fabricated in this work based on electrodeposition with over-oxidized polypyrrole nanoparticle (PPyox-CFE), which was applied successfully for real-time monitoring of quantal exocytosis from individual pheochromocytoma (PC12) cells. PPyox-CFE was evaluated by dopamine (DA) solutions through cyclic voltammetry and amperometry electrochemical methods, and results revealed that PPyox-CFE improved the detection limit of DA.

View Article and Find Full Text PDF

Electrochemical oxidation of pemetrexed (PMX) was studied on bare, carboxylic acid functionalized multi-walled carbon nanotubes and over-oxidized polypyrrole modified (oo-PPy/MWCNTs-COOH/GCE) glassy carbon electrodes by cyclic and adsorptive stripping differential pulse voltammetric techniques. The oo-PPy/MWCNTs-COOH/GCE is very sensitive to the oxidation of PMX. The results proved that the over-oxidation of the PPy film gave a negative charge density on porous layer that improved the adsorption for PMX.

View Article and Find Full Text PDF

An ascorbic acid amperometric sensor using over-oxidized polypyrrole and palladium nanoparticles composites.

Biosens Bioelectron

December 2012

State Key Laboratory of Transducer, Institute of Electronics, Chinese Academy of Science, Beijing 100190, PR China.

We constructed a highly responsive ascorbic acid (AA) sensor utilizing over-oxidized polypyrrole (OPPy) and Palladium nanoparticles (PdNPs) composites (OPPy-PdNPs). In the presence of PdNPs, polypyrrole (PPy) was coated on a gold (Au) electrode through cyclic voltammetry (CV) and over-oxidized at a fixed potential in NaOH solution. The PdNPs were characterized using ultraviolet-visible (UV-vis) spectrum and transmission electron microscopy (TEM).

View Article and Find Full Text PDF

Electrode-supported hydrogels were conferred with the biospecificity of enzymes during the process of electropolymerization to give rise to a class of bioactive, stimuli-responsive co-joined interpenetrating networks of inherently conductive polymers and highly hydrated hydrogels. Glucose responsive biotransducers were prepared by potentiostatic electropolymerization [750 mV vs. Ag/AgCl (3 M KCl)] of pyrrole at Poly(hydoxyethyl methacrylate)-based hydrogel-coated Pt micro-electrodes (Φ = 100 μm) from aqueous solutions of pyrrole and glucose oxidase (GOx; 0.

View Article and Find Full Text PDF

Nonenzymatic glucose sensor based on over-oxidized polypyrrole modified Pd/Si microchannel plate electrode.

Biosens Bioelectron

January 2011

Laboratory of Polar Materials and Devices, Ministry of Education, and Department of Electronic Engineering, East China Normal University, Shanghai 200241, China.

A silicon microchannel plate (MCP) array electrode modified with over-oxidized polypyrrole (OPPy) has been fabricated to detect glucose. The morphology and structure of the electrode are characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The OPPy modified silicon MCP array electrode exhibits high electrocatalytic activity as well as excellent selectivity to the electrochemical oxidation of glucose.