A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Benchmarking glucose results through automation: the 2009 Remote Automated Laboratory System Report. | LitMetric

Benchmarking glucose results through automation: the 2009 Remote Automated Laboratory System Report.

J Diabetes Sci Technol

Medical Automation Systems, Charlottesville, Virginia 2290, USA.

Published: November 2010

Background: Hyperglycemia in the adult inpatient population remains a topic of intense study in U.S. hospitals. Most hospitals have established glycemic control programs but are unable to determine their impact. The 2009 Remote Automated Laboratory System (RALS) Report provides trends in glycemic control over 4 years to 576 U.S. hospitals to support their effort to manage inpatient hyperglycemia.

Methods: A proprietary software application feeds de-identified patient point-of-care blood glucose (POC-BG) data from the Medical Automation Systems RALS-Plus data management system to a central server. Analyses include the number of tests and the mean and median BG results for intensive care unit (ICU), non-ICU, and each hospital compared to the aggregate of the other hospitals.

Results: More than 175 million BG results were extracted from 2006-2009; 25% were from the ICU. Mean range of BG results for all inpatients in 2006, 2007, 2008, and 2009 was 142.2-201.9, 145.6-201.2, 140.6-205.7, and 140.7-202.4 mg/dl, respectively. The range for ICU patients was 128-226.5, 119.5-219.8, 121.6-226.0, and 121.1-217 mg/dl, respectively. The range for non-ICU patients was 143.4-195.5, 148.6-199.8, 145.2-201.9, and 140.7-203.6 mg/dl, respectively. Hyperglycemia rates of >180 mg/dl in 2008 and 2009 were examined, and hypoglycemia rates of <40 mg/dl (severe) and <70 mg/dl (moderate) in both 2008 and 2009 were calculated.

Conclusions: From these data, hospitals can determine the current state of glycemic control in their hospital and in comparison to other hospitals. For many, glycemic control has improved. Automated POC-BG data management software can assist in this effort.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3005063PMC
http://dx.doi.org/10.1177/193229681000400627DOI Listing

Publication Analysis

Top Keywords

2009 remote
8
remote automated
8
automated laboratory
8
laboratory system
8
glycemic control
8
2008 2009
8
mg/dl range
8
benchmarking glucose
4
glucose automation
4
0
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!