Vascular access-site complications are an important cause of morbidity following catheterization procedures. Manual compression is the "gold standard" in achieving hemostasis of an arteriotomy site; however, manual compression is limited by the need to interrupt anticoagulation, prolonged bed rest, patient discomfort and time demands for healthcare providers. Vascular closure devices (VCDs) improve patient comfort, free medical staff resources and shorten the time needed for hemostasis, ambulation and discharge. However, the safety of VCDs remains in question and they may increase the risks of infection and leg ischemia. Compared with manual compression, the rate of major complications appears to be increased with VasoSeal, decreased with Angio-Seal and decreased in diagnostic cases with Perclose. The safety of VCDs cannot be assumed due to "class effect," and nearly all individual trials are underpowered to detect differences in complication rates, so the safety of other individual VCDs is unclear. In the absence of puncture site-related risk factors, VCDs as a whole appear to have little influence on complication rates, and patients at high baseline risk for bleeding due to clinical factors may benefit from these devices. Screening with femoral angiography prior to VCD placement and avoidance of VCDs in the presence of puncture site-related risk factors might reduce the risk of vascular complications. This review describes the mechanism, efficacy and safety of VCDs including hemostasis pads, the FemoStop, Clamp Ease, Mynx, Duett, FISH, Boomerang, ExoSeal, Starclose, VasoSeal, Angio-Seal and Perclose devices.
Download full-text PDF |
Source |
---|
Diagnostics (Basel)
January 2025
Faculty of Applied Science, Uplands College of Science and Technology Incorporated (UCSI), No. 1, Jalan Menara Gading, Kuala Lumpur 56000, Malaysia.
: This study compares system-reported organ doses (ODs) to manually calculated mean glandular doses (MGDs) in mammography across multiple centers and manufacturers in Dubai. : A retrospective study of 2754 anonymized mammograms from six clinics in Dubai were randomly retrieved from a central dose survey database. Organ doses were documented along with other dosimetry information like kVp, mAs, filter, target, compression force, and breast thickness.
View Article and Find Full Text PDFJ Contemp Dent Pract
September 2024
Department of Prosthodontics, Bharati Vidyapeeth (Deemed to be University) Dental College and Hospital, Sangli, Maharashtra, India, ORCID: https://orcid.org/0000-0002-6661-0931.
Aim: The aim of this systematic review was to evaluate the effect of build orientation on the mechanical and physical properties of additively manufactured resin using digital light processing (DLP).
Background: The properties of 3D-printed materials are influenced by various factors, including the type of additive manufacturing (AM) system and build orientation. There is a scarcity of literature on the effect of build orientation on the mechanical and physical properties of additively manufactured resins using DLP technology in dentistry.
Ann Thorac Surg Short Rep
December 2024
Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.
Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.
View Article and Find Full Text PDFMagn Reson Med
January 2025
Department of Radiology & Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Purpose: To correct maternal breathing and fetal bulk motion during fetal 4D flow MRI.
Methods: A Doppler-ultrasound fetal cardiac-gated free-running 4D flow acquisition was corrected post hoc for maternal respiratory and fetal bulk motion in separate automated steps, with optional manual intervention to assess and limit fetal motion artifacts. Compressed-sensing reconstruction with a data outlier rejection algorithm was adapted from previous work.
Cardiovasc Intervent Radiol
January 2025
Department of Vascular and Endovascular Surgery, The Affiliated Suzhou Hospital of Nanjing Medical University, 242 Guangji Road, Gusu District, Suzhou, 215000, China.
Purpose: To describe the downsizing post-closure technique for access hemostasis during emergency endovascular repair (EVAR) in ruptured abdominal aortic aneurysms (RAAA).
Materials And Methods: A cohort of eight patients underwent emergency EVAR through 16 femoral access sites for infrarenal RAAA. The downsizing post-closure technique, which involves a reduction in the size of the large-bore access by advancing a 10F sheath, was consistently applied.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!