Polyelectrolyte multilayer capsules have recently gained interest as carriers for drug delivery. When envisioning mucosal administration, one is focused with potential concerns such as tissue irritation and tissue damage, induced by the carrier itself. In this paper we demonstrate the use of a slug-based (Arion lusitanicus) assay to evaluate the mucosal irritation potential of different types of polyelectrolytes, their complexes and multilayer capsules. This assay allows to assess in a simple yet efficient way mucosal tissue irritation without using large numbers of vertebrates such as mice, rabbits or non-human primates. We found that although single polyelectrolyte components do induce tissue irritation, this response is dramatically reduced upon complexation with an oppositely charged polyelectrolyte, rendering fairly inert polyelectrolyte complexes. These findings put polyelectrolyte multilayer capsules further en route towards drug delivery applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.biomaterials.2010.11.012 | DOI Listing |
Acta Biomater
January 2025
National Engineering Research Center of Ophthalmology and Optometry, School of Biomedical Engineering, School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, China. Electronic address:
Posterior capsule opacification (PCO) is the most common complication after cataract surgery. It is primarily caused by the proliferation, migration, and adhesion of residual lens epithelial cells within the capsular bag following phacoemulsification and intraocular lens (IOL) implantation. Although investigations of surface modification onto IOL have partially reduced PCO development in recent years, there are still challenges in long-term efficacy and intraocular biocompatibility.
View Article and Find Full Text PDFLangmuir
December 2024
Joint Research Centre on Medicine, Xiangshan Hospital of Wenzhou Medical University, Ningbo, Zhejiang 315700, China.
The intracellular fate of drug carriers had received extensive attention, which was profoundly influenced by the shapes of carriers. However, it has not been fully addressed due to the lack of effective strategies to prepare carriers with different shapes and the interference of other parameters (such as stiffness and chemistry of the shaped particle and the different cell lines). In this work, polymer-based microcapsules with different shapes (spherical, peanut, dumbbell, and cubic) but the same surface chemistry were engineered through the alternative deposition of polyethylenimine (PEI) and polyethylene glycol (PEG) onto the sacrificial CaCO templates with different well-defined shapes.
View Article and Find Full Text PDFInt J Biol Macromol
November 2024
School of Materials Science and Engineering, Zhengzhou University, Zhengzhou 450001, China; Henan Key Laboratory of Advanced Nylon Materials and Application, Zhengzhou University, Zhengzhou 450001, China. Electronic address:
Hollow natural polysaccharide microcapsules have broad applications in drug delivery field due to their excellent biocompatibility and drug loading efficiency. In this paper, pH/near-infrared (NIR) dual-responsive microcapsules composed of hyaluronic acid (HA), chitosan (CS) and hollow CuS (HA/CS/HA@CuS) had been fabricated via a layer-by-layer (LbL) approach. The negative charge, rough surface and hollow structure of microcapsules are very favorable for loading positively charged DOX.
View Article and Find Full Text PDFEndosc Ultrasound
August 2024
Department of Gastroenterology, National Clinical Research Center for Digestive Diseases, Shanghai Key Laboratory of Nautical Medicine and Translation of Drugs and Medical Devices, Changhai Hospital; National Key Laboratory of Immunity and Inflammation, Naval Medical University, Shanghai, China.
Background And Objectives: EUS is an important modality for diagnosis and assessment of gastrointestinal (GI) subepithelial lesions. However, EUS is invasive and operator-dependent and requires sedation in most cases. The newly developed ultrasound capsule endoscopy (USCE) system, with both white-light and ultrasound imaging modalities, is a minimally invasive method for superficial and submucosal imaging of the esophagus.
View Article and Find Full Text PDFInt J Pharm
October 2024
Biomaterials Research Laboratory (BMRL), Department of Chemical Engineering, Faculty of Engineering and Technology, SRM Institute of Science and Technology, Kattankulathur - 603203, Chengalpattu, Tamil Nadu, India. Electronic address:
The fabrications of hollow microcapsules (MCs) with new architecture and ability to incorporate different nanomaterials have received great interest for targeted cancer therapy. Recently, CuS based nanomaterials have been demonstrated to possess the ability to mimic Fenton-like activity in tumor environment and inducing cancer cell apoptosis by generating highly reactive oxygen species (ROS). In this study, we have developed poly(allylamine) hydrochloride (PAH)/dextran sulfate (DS) polyelectrolyte MCs capable of carrying doxorubicin (DOX) for targeted cancer therapy and ultrasound imaging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!