Background: Scapular notching, erosion of the scapular neck related to impingement by the medial rim of the humeral cup during adduction, is a radiographic sign specific to reverse shoulder arthroplasty (RSA). Its clinical and radiological consequences remain unclear.
Questions/purposes: Therefore, we: (1) determined the incidence of notching in a large series, (2) described the natural history of notching, (3) determined whether notching is related to functional scores or (4) radiographic signs of failure, and (5) identified factors related to notch development.
Patients And Methods: We retrospectively reviewed 448 patients who underwent a Grammont-type RSA (461 shoulders) with a mean followup of 51 months (range, 24-206 months). RSA was implanted for cuff tear arthropathy or osteoarthritis with cuff deficiency. We assessed scapular notching using AP views standardized under fluoroscopy. Clinical assessment included Constant-Murley score and range of motion. Aside from notching, radiographic assessment included evaluation of humeral and glenoid radiolucent lines.
Results: Notching occurred in 68% of cases. It appeared early, but its later evolution was variable. Notching was associated with followup, strength, passive and active elevation, humeral radiolucent lines, and glenoid lucent lines. It also correlated with a higher rate in patients with preoperative superior erosion.
Conclusions: Scapular notching is frequent, generally progresses, and is associated with deterioration of some clinical parameters and radiolucent lines. We believe the preoperative pattern of glenoid erosion is of particular importance due to its influence on the surgeon's glenoid preparation and base-plate positioning. It is crucial to avoid cranial position and superior tilt.
Levels Of Evidence: Level IV, Therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3148391 | PMC |
http://dx.doi.org/10.1007/s11999-010-1695-8 | DOI Listing |
J Clin Med
January 2025
Shoulder and Elbow Surgery, Schulthess Clinic Zürich, 8008 Zürich, Switzerland.
: Classical reverse shoulder arthroplasty (RSA) with a high neck-shaft angle (NSA) of 155° has shown satisfactory outcomes. However, newer RSA designs aim to improve results by modifying the stem design. This study evaluates the 5-year outcomes of a stem design featuring a rectangular metadiaphyseal fixation and a 135° NSA.
View Article and Find Full Text PDFJ Clin Orthop Trauma
March 2025
Department of Orthopaedics, Woodend Hospital, Aberdeen, AB15 6XS, UK.
Reverse shoulder arthroplasty (RSA) has witnessed a significant advancement with the introduction of lateralisation techniques, aiming to enhance shoulder function and implant durability. Traditional medialised designs, following Grammont's principles, have encountered challenges such as scapular notching, reduced rotational strength, and instability. In contrast, lateralisation methods, which reposition the joint center of rotation laterally on the glenoid, humerus, or both, seek to improve deltoid leverage, optimize the rotator cuff muscles' length-tension relationship, and enhance joint stability.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
January 2025
Palm Beach Shoulder Service HCA Florida Atlantis Orthopedics, Palm Beach, FL, USA; JFK/University of Miami Department of Orthopedics, Lake Worth, FL, USA. Electronic address:
Background: Glenoid bone loss presents a complex challenge in the management of patients with glenohumeral osteoarthritis (GHOA) undergoing Reverse Shoulder Arthroplasty (RSA). Eccentric reaming and bone grafting have been utilized to address this issue but are associated with their own set of challenges. This study explores the effectiveness of augmented glenoid baseplate RSA in addressing glenoid bone loss.
View Article and Find Full Text PDFCurr Rev Musculoskelet Med
January 2025
Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA.
Purpose Of Review: With the growing popularity and broadening indications for Reverse Shoulder Arthroplasty (RSA), increasing modularity in design and adjustments to each component can enhance postoperative range of motion (ROM), thus expanding treatment capabilities. This review outlines the advancements developed to optimize ROM through modifications in glenoid and humeral components and the integration of computational tools for surgical planning.
Recent Findings: Enhancements in glenoid component design aim to mitigate complications like scapular notching and improve ROM, particularly in abduction and external rotation.
Tunis Med
December 2024
Department of trauma and orthopedics surgery. Mouwasat Hospital Dammam, 32263 Eastern Province Kingdom of Saudi Arabia.
Unlabelled: Introduction-Aim: Full-polyethylene glenosphere reverse shoulder arthroplasty (FP-RSA) known commonly as inverted-bearing concept utilizes a polyethylene glenosphere and metallic humeral liner. The aim was to assess mid-term outcomes of FP-RSA focusing on the incidence of scapular notching.
Methods: A retrospective analysis of 24 consecutive primary FP-RSA performed between 2017 and 2020 was conducted.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!