Objective: Functional preload parameters such as stroke-volume variation (SVV) and pulse-pressure variation (PPV) are superior to filling pressures when assessing volume responsiveness in mechanically ventilated patients. This investigation studied their application in the setting of acute myocardial ischemia and reperfusion (I/R).

Design And Setting: Experimental animal study in a university laboratory.

Participants: Twenty anesthetized and ventilated pigs.

Interventions: A temporary reduction of preload was obtained by ventilation with a positive end-expiratory pressure of 10 cmH(2)O. Ischemia was induced by temporary occlusion of the left anterior descending coronary artery for 60 minutes and was followed by 30 minutes of reperfusion.

Measurements And Main Results: Animals were instrumented with an ultrasonic aortic flow probe to monitor stroke volume (SV) and SVV. Arterial pressure and PPV were recorded with a microtip catheter; left ventricular volume and pressure were registered by a conductance catheter. Respective hemodynamic measurements were made before, during, and after PEEP; before and after the induction of I/R. Eleven animals survived I/R and were analyzed. Before I/R, SVV (r = 0.87, p < 0.001) and PPV (r = 0.75, p < 0.05) during PEEP correlated significantly with relative changes in SV caused by the release of PEEP. Changes in SVV (r = 0.82, p < 0.01) and PPV (r = 0.67, p < 0.05) correlated significantly with relative changes in SV. After I/R, neither the relations between changes in SV to SVV or PPV during PEEP nor the relations between changes in SVV or PPV to changes in SV reached significance.

Conclusions: SVV and PPV did not reflect volume responsiveness in an experimental model of acute myocardial I/R.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jvca.2010.09.001DOI Listing

Publication Analysis

Top Keywords

volume responsiveness
12
acute myocardial
12
changes svv
12
svv ppv
12
reflect volume
8
myocardial ischemia
8
ischemia reperfusion
8
correlated relative
8
relative changes
8
relations changes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!