Substrate diameter and compliance affect the gripping strategies and locomotor mode of climbing boa constrictors.

J Exp Biol

Department of Biological Sciences, University of Cincinnati, PO Box 210006, Cincinnati, OH 45221-0006, USA.

Published: December 2010

Arboreal habitats pose unique challenges for locomotion as a result of their narrow cylindrical surfaces and discontinuities between branches. Decreased diameter of branches increases compliance, which can pose additional challenges, including effects on stability and energy damping. However, the combined effects of substrate diameter and compliance are poorly understood for any animal. We quantified performance, kinematics and substrate deformation while boa constrictors (Boa constrictor) climbed vertical ropes with three diameters (3, 6 and 9 mm) and four tensions (0.5, 1.0, 1.5 and 2.0 body weights). Mean forward velocity decreased significantly with both decreased diameter and increased compliance. Both diameter and compliance had numerous effects on locomotor kinematics, but diameter had larger and more pervasive effects than compliance. Locomotion on the largest diameter had a larger forward excursion per cycle, and the locomotor mode and gripping strategy differed from that on the smaller diameters. On larger diameters, snakes primarily applied opposing forces at the same location on the rope to grip. By contrast, on smaller diameters forces were applied in opposite directions at different locations along the rope, resulting in increased rope deformation. Although energy is likely to be lost during deformation, snakes might use increased surface deformation as a strategy to enhance their ability to grip.

Download full-text PDF

Source
http://dx.doi.org/10.1242/jeb.047225DOI Listing

Publication Analysis

Top Keywords

diameter compliance
12
substrate diameter
8
locomotor mode
8
boa constrictors
8
decreased diameter
8
diameter larger
8
smaller diameters
8
compliance
6
diameter
6
compliance affect
4

Similar Publications

Introduction The study aimed to retrospectively evaluate the early patient outcome and left ventricular function after mitral valve replacement with a tilting disc valve and total preservation. Patients and methods This retrospective observational study includes patients who underwent mitral valve replacement using a tilting disc valve with total preservation of mitral valvular and subvalvular apparatus from July 2021 to August 2022 at a single center. Results The data were reviewed retrospectively for age, sex, comorbidities, operating time, aortic cross-clamp time, cardiopulmonary bypass time, preoperative and postoperative left ventricular ejection fraction, mean gradient across the mitral valve, left ventricular diameter, left atrial size, atrial fibrillation, complications, mortality, and early patient outcome.

View Article and Find Full Text PDF

Introduction Spinal fusion surgery with pedicle screws is commonly performed to stabilize the spine of osteoporotic patients. However, securing a strong screw fixation in osteoporotic bone presents significant challenges due to the reduced bone density. This study aimed to compare the biomechanical performance in an osteoporotic bone model of pedicle screws inserted using two different techniques, the Jamshidi needle technique and the pedicle probe technique, as well as the influence of tapping on both these techniques.

View Article and Find Full Text PDF

Stone-event-free survival after retrograde intrarenal surgery: is the stone-free-status so relevant for the future outcomes?

Int Urol Nephrol

December 2024

Department of Urology, Unidade Local de Saúde de Santo António, Centro Hospitalar Universitário Do Porto, 8th floor, Largo Do Prof. Abel Salazar, 4099-001, Porto, Portugal.

Introduction: The primary aim of stone treatment is to achieve stone-free status. Residual fragments can cause stone growth, recurrence, urinary tract infections, and ureteric obstruction. Our goal was to describe the natural history of stone burden after retrograde intrarenal surgery (RIRS) based on stone-free status (SFS), evaluating stone growth and stone-events.

View Article and Find Full Text PDF

A Novel Pneudraulic Actuation Method to Enhance Soft Robot Control.

Soft Robot

December 2024

Department of Surgical & Interventional Engineering, School of Biomedical Engineering & Imaging Sciences, King's College London (KCL), London, UK.

Modern industrial and medical applications require soft actuators with practical actuation methods, capable of precision control and high-speed performance. Within the realm of medical robotics, precision and speed imply less complications and reduced operational times. Soft fluidic actuators (SFAs) are promising candidates to replace the current rigid endoscopes due to their mechanical compliance, which offers safer human-robot interaction.

View Article and Find Full Text PDF

Introduction: Bone remodeling around implants in implant-supported rehabilitation is a continuous debate with no consensus in the literature. This study aimed to investigate the implant- and patient-specific factors contributing to marginal bone loss near the implant.

Materials And Methods: We included patients who had implant-supported prosthetic rehabilitation using one implant system, between 2014 and 2018, who had full follow-up documentation and orthopantomography over five years, and who had no unwell-controlled systemic pathologies that may influence bone metabolism.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!