Herein, a rapid electrochemical biosensor for L-histidine based on highly specific, L-histidine-dependent DNAzymes is described. DNA with a single, sessile ribo-adenine, self-cleaves in the presence of L-histidine, allowing a ferrocene tag to transfer electrons to the electrode. The double-stranded DNA complex was chemi-absorbed to a gold electrode via a 3' terminal thiol. The signal of this proposed sensor is linear over the range, 1 nM to 10 μM, with R=0.98775. To improve signal intensity, gold nanoparticles were anchored to a gold electrode surface which had been previously modified with self-assembled monolayers of 1,6-hexanedithiol. With gold nanoparticle modification, a lower detection limit of 0.1 pM L-histidine and a good linear relationship over the range, 0.1 pM to 50 nM were obtained. The proposed biosensor presents high specificity for L-histidine, is not affected by the presence of other amino acids, and demonstrates excellent enantio-selectivity toward L-histidine. This proposed sensor protocol offers reasonable selectivity, rapid speed, and operational convenience for real sample assays.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2010.10.041 | DOI Listing |
Biomed Microdevices
January 2025
Department of Physics, Faculty of Philosophy, Science and Letter, University of São Paulo, Ribeirão Preto, SP, 14040-901, Brazil.
The overexpression of Human Epidermal Growth Factor Receptor 2 (HER2) protein is specifically related to tumor cell proliferation in breast cancers. Its presence in biological serum samples indicates presence or progression of cancer, becoming a promise biomarker. However, their detection needs a simple and high accuracy platform.
View Article and Find Full Text PDFChempluschem
January 2025
Jiangsu Agri-animal Husbandry Vocational College, Department of Pharmacy, CHINA.
With enrichment of tetracycline (TC) in ecosystems, its accurate detection has become a major concern. Noble-metal nano-particles have attracted great interest as potential materials for sensing applications because of their remarkable electrical properties and adaptability. Herein, a novel electro-chemical detection technique based on carbon nano-tubes (CNTs) as the support material is developed to detect TC with high precision.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Department of Physics, School of Electrical and Electronics Engineering, SASTRA Deemed to be University, Thanjavur 613 401, Tamil Nadu, India.
This study presents the fabrication of highly conducting Au fabric electrodes using a layer-by-layer (LBL) approach and its application toward energy storage. Through the ligand-exchange mechanism, the alternating layers of tris(2-aminoethyl)amine (TREN) and gold nanoparticles (Au NPs) encapsulated with tetraoctylammonium bromide (TOABr) ligands (Au-TOABr) were deposited onto the fabric to achieve a highly conducting Au fabric (0.12 Ω/□) at room temperature in just two LBL cycles.
View Article and Find Full Text PDFJ Agric Food Chem
January 2025
College of Chemistry and Chemical Engineering, Jishou University, Jishou, Hunan 416000, P. R. China.
Detecting β-lactoglobulin (β-Lg) with high sensitivity and selectivity is an urgent requirement due to nearly 80% of milk anaphylaxis, such as respiratory tract, skin urticaria, and gastrointestinal disorders, being caused by β-Lg. An ultrasensitive β-Lg electrochemical aptasensor utilizing core-satellite gold nanoparticle@silver nanocluster (AuNPs@AgNCs) nanohybrids as electrocatalysts was developed. First, β-Lg aptamer was anchored on gold electrodes and AuNPs to obtain high selectivity.
View Article and Find Full Text PDFAnalyst
January 2025
Department of Applied Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama, Kanagawa 223-8522, Japan.
A paper-based potentiometric sensor integrated with a polymeric hydrogel has been developed for sodium ion (Na) determination in human urine. The construction of an all-solid-state ion selective electrode (s-ISE) and an all-solid-state reference electrode (s-RE) on a photo paper substrate was achieved using an inkjet printing method. For s-ISE fabrication, carbon nanotubes (CNTs) and gold nanoparticles (AuNPs) were printed on the substrate as a nanocomposite solid contact.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!