A miniature mass analyser for in-situ elemental analysis of planetary material-performance studies.

Anal Bioanal Chem

Space Research and Planetology, Institute of Physics, Sidlerstrasse 5, University Bern, 3012 Bern, Switzerland.

Published: February 2011

The performance of a laser ablation mass analyser designed for in-situ exploration of the chemical composition of planetary surfaces has been investigated. The instrument measures the elemental and isotopic composition of raw solid materials with high spatial resolution. The initial studies were performed on NIST standard materials using IR laser irradiance (< 1 GW cm(-2)) at which a high temporal stability of ion formation and sufficiently low sample consumption was achieved. Measurements of highly averaged spectra could be performed with typical mass resolution of m/Δm ≈ 600 in an effective dynamic range spanning seven decades. Sensitive detection of several trace elements can be achieved at the ~ ppm level and lower. The isotopic composition is usually reproduced with 1% accuracy, implying good performance of the instrument for quantitative analysis of the isotopic fractionation effects caused by natural processes. Using the IR laser, significant elemental fractionation effects were observed for light elements and elements with a high ionization potential. Several diatomic clusters of major and minor elements could also be measured, and sometimes these interfere with the detection of trace elements at the same nominal mass. The potential of the mass analyser for application to sensitive detection of elements and their isotopes in realistic samples is exemplified by measurements of minerals. The high resolution and large dynamic range of the spectra makes detection limits of ~100 ppb possible.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-010-4411-3DOI Listing

Publication Analysis

Top Keywords

mass analyser
12
isotopic composition
8
dynamic range
8
sensitive detection
8
detection trace
8
trace elements
8
fractionation effects
8
elements
6
miniature mass
4
analyser in-situ
4

Similar Publications

Despite significant advancements in sample preparation, instrumentation and data analysis, single-cell proteomics is currently limited by proteomic depth and quantitative performance. Here we demonstrate highly improved depth of proteome coverage as well as accuracy and precision for quantification of ultra-low input amounts. Using a tailored library, we identify up to 7,400 protein groups from as little as 250 pg of HeLa cell peptides at a throughput of 50 samples per day.

View Article and Find Full Text PDF

Determinants of cerebrospinal fluid leakage in a large cohort of macroprolactinomas.

Ann Endocrinol (Paris)

January 2025

Assistance Publique Hôpitaux de Paris, Pituitary Unit, Pitié-Salpêtrière Hospital, 75013 Paris, France. Electronic address:

Background: Non-functional adrenal incidentaloma (NFAI) is associated with increased risk of adverse cardiometabolic outcome. Identifying predictors of atherosclerotic cardiovascular disease (ASCVD) may enable more appropriate management strategies in patients with NFAI. We aimed to investigate body composition parameters and ASCVD risk in patients with NFAI.

View Article and Find Full Text PDF

Phospholipase A2 receptor 1 (PLA2R1) exists in many animals and plays an important role in membranous nephropathy. In this study, we aimed to evaluate a PLA2R1 knock-in rat model with repaired kidney function to study the molecular mechanisms of membranous nephropathy. We constructed the PLA2R1 knockout [PLA2R1(-)] model and PLA2R1 knock in [PLA2R1(+)] model in rats.

View Article and Find Full Text PDF

Increased cardiovascular risk despite unchanged body composition in NFAI.

Ann Endocrinol (Paris)

January 2025

University of Health Sciences, Gulhane Faculty of Medicine, Department of Endocrinology and Metabolism, Ankara, Turkey.

Background: Non-functional adrenal incidentaloma (NFAI) is associated with an increased risk of adverse cardiometabolic outcome. Identifying predictors of atherosclerotic cardiovascular disease (ASCVD) may enable more appropriate management strategies in patients with NFAI. We aimed to investigate the body composition parameters and ASCVD risk in patients with NFAI.

View Article and Find Full Text PDF

Differentiation of the chronic lymphocytic leukemia response to ibrutinib and acalabrutinib treatment by single-cell MALDI-TOF MS imaging.

J Pharm Biomed Anal

January 2025

Clinical Institute of Laboratory Diagnostics, University Hospital Centre Osijek, J. Huttlera 4, Osijek 31 000, Croatia; Faculty of Medicine Osijek, JJ Strossmayer University of Osijek, J. Huttlera 4, Osijek 31 000, Croatia. Electronic address:

Ibrutinib and acalabrutinib, Bruton's tyrosine kinase inhibitors (BTKi) used for chronic lymphocytic leukemia (CLL) treatment, aim the same target but their off-target effects are different. The aim of this study was to use single-cell MALDI TOF mass spectrometry imaging to compare the CD19+ lymphocytes' mass spectra in untreated and ibrutinib- or acalabrutinib-treated subjects in order to better understand the therapeutic effect of BTKi. 180 cells from 9 male subjects divided in 3 groups (untreated, ibrutinib-treated and acalabrutinib-treated) were analyzed using MALDI-TOF mass spectrometry analyzer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?