Background: Olfactomedin (Olfm) is a member of a diverse group of extracellular matrix proteins important for neuronal growth. Recent microarray studies identified Olfm as one of the down-regulated transcripts in receptive endometrium at the time of embryo attachment and implantation. However, the underlying molecular mechanisms that govern Olfm expression and its effect on embryo attachment and implantation remain unknown.
Methods: The expression of Olfm in the human endometrium was investigated by real-time PCR, western blotting and immunohistochemistry on human endometrial biopsies from natural and ovarian stimulated cycles. To investigate the function of Olfm in trophoblast-endometrial cell attachment, an in vitro spheroid-endometrial cell co-culture study was performed.
Results: Human endometrial Olfactomedin-1 and -2(Olfm-1 and -2) transcripts decreased significantly from the proliferative to the secretory phases of the menstrual cycle. Olfm protein was strongly expressed in the luminal and glandular epithelium and moderately in the stromal cells of human endometria. Ovarian stimulation significantly decreased (P < 0.05) the expression of endometrial Olfm-1 and -2 transcripts in patients receiving IVF treatment when compared with those in the natural cycle. Importantly, recombinant Olfm-1 suppressed JAr spheroid attachment onto Ishikawa cells and this was not associated with changes of β-catenin and E-cadherin expression in trophoblast and endometrial cells.
Conclusions: Decreased expression of Olfm during the receptive phase of the endometrium may allow successful trophoblast attachment for implantation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/humrep/deq298 | DOI Listing |
BMC Oral Health
January 2025
Removable Prosthodontics Department, Faculty of Dentistry, October 6 University, Giza, Egypt.
Background: The continuous development in digital prosthodontics allowed the customization of attachments and retentive inserts which offers an easy and cheap solution for regular maintenance of locator overdentures during daily practice. The present study compared the change in retention values of the fully digitally manufactured custom-made locator attachment retentive insert with the ready-made ones after insertion, removal, and masticatory cycles.
Methods: A complete denture was constructed over a mandibular edentulous epoxy model.
Ecotoxicol Environ Saf
January 2025
Korea Institute of Toxicology, Daejeon 34114, Republic of Korea. Electronic address:
N-(1,3-Dimethylbutyl)-N'-phenyl-p-phenylenediamine (6PPD), a synthetic additive widely used in the rubber industry, and its oxidized product 6PPD-quinone (6PPDQ), have garnered widespread attention as an emerging hazardous chemicals owing to their potential detrimental effects on aquatic ecosystem and human health. The effects of 6PPD and 6PPDq on the female reproductive tract, especially embryo implantation, remain unknown and were investigated in this study. We used the spheroid attachment and outgrowth models of BeWo trophoblastic spheroids and Ishikawa cells as surrogates for the human blastocyst and endometrial epithelium, respectively.
View Article and Find Full Text PDFArthroplast Today
February 2025
Department of Orthopaedic Surgery, Fiona Stanley Fremantle Hospitals Group, Murdoch, Western Australia, Australia.
Background: Dual mobility (DM) implants in total hip arthroplasty provide excellent range of motion with low dislocation rates. A complication of this design is intraprosthetic dislocation (IPD), where the polyethylene (PE) liner dissociates from the femoral head. In older designs, IPD occurred due to a small head size and late PE wear with head-capture-mechanism failure.
View Article and Find Full Text PDFJ Dent Sci
December 2024
Liaison Center for Innovative Dentistry, Graduate School of Dentistry, Tohoku University, Sendai, Japan.
Background/purpose: Titanium (Ti) is extensively used in dental and orthopedic implants due to its excellent mechanical properties. However, its smooth and biologically inert surface does not support the ingrowth of new bone, and Ti ions may have adverse biological effects. The purpose is to improve the corrosion resistance of titanium and create a 3D structured coating to enhance osseointegration through a very simple and fast surface treatment.
View Article and Find Full Text PDFExp Eye Res
January 2025
Casey Eye Institute, Oregon Health & Science University, United States.
Animal models that help us understand how elevated intraocular pressure (IOP) causes axonal injury will lead to new glaucoma therapies. Because reliable measurements are difficult to obtain in chronic models, we developed the controlled elevation of IOP (CEI) approach. Here, a cannula connected to an elevated balanced salt solution (BSS) reservoir is inserted into the anterior chamber of anesthetized Brown Norway rats.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!