A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Efficacy and safety assessment of a novel ultraviolet C device for treating corneal bacterial infections. | LitMetric

Background: A prototype solid-state Ultraviolet-C (UVC) LED device may be useful in the treatment of corneal microbial infections, as UVC is commonly used for eradicating bacteria, fungi and viruses in other settings. This study assessed the efficacy of 265 nm UVC from this LED, on four different bacterial strains, and investigated the consequences of corresponding exposures on human corneal epithelial cells in vitro.

Methods: Agar plate lawns of Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa and Streptococcus pyogenes were exposed to a 4.5 mm diameter 265 nm UVC beam at a fixed intensity and distance, for 30, 5, 4, 2 and 1 seconds. Growth inhibition was assessed with a BioRad Gel imager, and the diameter of lucent areas of bacterial inhibition recorded. Human corneal epithelial cells cultured on glass cover-slips were exposed to corresponding doses of UVC from the same device. Live/dead staining was performed and the results quantified.

Results: There was 100% inhibition of growth for all bacteria tested, at all exposure times. A 30-second exposure of human corneal epithelium to UVC gave no statistically significant decrease (P = 0.877) in the ratio of live to dead cells when compared to control cultures.

Conclusion: The results confirmed that a 1 second exposure to germicidal UVC from this LED source was sufficient to inhibit microbial proliferation in the four bacterial strains tested in vitro. The literature suggests UVC at this dose could potentially be beneficial in treating corneal surface infections, without causing significant adverse effects, supported by our findings in human corneal epithelium exposed to UVC.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1442-9071.2010.02471.xDOI Listing

Publication Analysis

Top Keywords

human corneal
16
uvc led
12
uvc
9
treating corneal
8
265 uvc
8
bacterial strains
8
corneal epithelial
8
epithelial cells
8
corneal epithelium
8
corneal
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!