Background: one variable that may influence cardiac resynchronization therapy response is the programmed atrioventricular (AV) delay. The SmartDelay determined av optimization: a comparison to other AV delay methods used in cardiac resynchronization therapy (SMART-AV) trial prospectively randomized patients to a fixed empirical AV delay (120 milliseconds), echocardiographically optimized AV delay, or AV delay optimized with SmartDelay, an electrogram-based algorithm.

Methods And Results: a total of 1014 patients (68% men; mean age, 66 ± 11 years; mean left ventricular ejection fraction, 25 ± 7%) who met enrollment criteria received a cardiac resynchronization therapy defibrillator, and 980 patients were randomized in a 1:1:1 ratio. All patients were programmed (DDD-60 or DDDR-60) and evaluated after implantation and 3 and 6 months later. The primary end point was left ventricular end-systolic volume. Secondary end points included New York Heart Association class, quality-of-life score, 6-minute walk distance, left ventricular end-diastolic volume, and left ventricular ejection fraction. The medians (quartiles 1 and 3) for change in left ventricular end-systolic volume at 6 months for the SmartDelay, echocardiography, and fixed arms were -21 mL (-45 and 6 mL), -19 mL (-45 and 6 mL), and -15 mL (-41 and 6 mL), respectively. No difference in improvement in left ventricular end-systolic volume at 6 months was observed between the SmartDelay and echocardiography arms (P=0.52) or the SmartDelay and fixed arms (P=0.66). Secondary end points, including structural (left ventricular end-diastolic volume and left ventricular ejection fraction) and functional (6-minute walk, quality of life, and New York Heart Association classification) measures, were not significantly different between arms.

Conclusions: neither SmartDelay nor echocardiography was superior to a fixed AV delay of 120 milliseconds. The routine use of AV optimization techniques assessed in this trial is not warranted. However, these data do not exclude possible utility in selected patients who do not respond to cardiac resynchronization therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.110.992552DOI Listing

Publication Analysis

Top Keywords

left ventricular
32
cardiac resynchronization
24
resynchronization therapy
24
ventricular ejection
12
ejection fraction
12
ventricular end-systolic
12
end-systolic volume
12
smartdelay echocardiography
12
smartdelay determined
8
determined optimization
8

Similar Publications

Background: Left ventricular obstruction (LVO) is an infrequent complication following transcatheter aortic valve replacement (TAVR) that can lead to severe hemodynamic decompensation. Previous studies have analyzed the pathophysiology of this clinical entity; however, little is known about the anatomical characteristics as assessed by computational tomography (CT) of patients at risk.

Methods: Data from 349 patients were retrospectively analyzed from a single center registry of patients undergoing TAVR at San Raffaele Hospital, Milan, Italy, between January 2020 and December 2021.

View Article and Find Full Text PDF

Aims: Hypertrophic cardiomyopathy (HCM) is characterized by unexplained left ventricular hypertrophy (LVH) with key pathologic processes including myocardial necrosis, fibrosis, inflammation, and hypertrophy, which are involved in heart failure (HF), stroke, and even sudden death. Our aim was to explore the communication network among various cells in the heart of transverse aortic constriction (TAC) surgery induced HCM mice.

Materials And Methods: Single-cell RNA-seq data of GSE137167 was downloaded from the Gene Expression Omnibus (GEO) database.

View Article and Find Full Text PDF

Sepsis-induced cardiomyopathy (SICM) is a life-threatening complication of sepsis characterized by myocardial dysfunction. SICM significantly increases mortality rates in sepsis. Despite its clinical relevance, SICM lacks a unified definition and standardized diagnostic criteria, complicating early identification and treatment.

View Article and Find Full Text PDF

The guide extension-facilitated ostial stenting (GEST) technique uses a guide extension catheter (GEC) to improve stent delivery during primary coronary angioplasty (PCI). GECs are used for stent delivery into the coronary arteries of patients with difficult anatomy due to tortuosity, calcification, or chronic total occlusion (CTO) vessels. Stent and balloon placement has become challenging in patients with increasing lesion complexity due to tortuosity, vessel morphology, length of the lesion, and respiratory movements.

View Article and Find Full Text PDF

Left ventricular assist devices (LVADs) have been used as a bridge to transplantation in patients with advanced heart failure. In this case, LVAD therapy was used as a destination therapy for 16 years, representing the longest documented and continuously ongoing support with the original implanted device.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!