A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Respiration-induced changes in ear photoplethysmography relates to relative blood volume during hemodialysis. | LitMetric

Renal failure patients provide a good model of fluid overload with the process of hemodialysis leading to central hypovolemia. This study aims to assess if hemodialysis induces identifiable changes in ear photoplethysmographic waveform variability (PPGV). The results are based on data collected from 10 kidney failure patients undergoing regular hemodialysis; classified as either fluid removal or non-fluid removal patients. Six minutes of continuous photoplethysmography (PPG) signals were recorded at pre-dialysis, end of dialysis and at regular intervals of 20 minutes during hemodialysis. Baseline and amplitude variabilities were derived from the PPG waveform. Frequency spectrum analysis was applied to these variability signals and spectral powers were then calculated from low frequency (LF), mid frequency (MF) and high frequency (HF) bands. The results indicate that in fluid removal patients, LF (p = 0.04), MF (p = 0.03) and HF (p = 0.0003) powers of amplitude ear PPGV (expressed in mean-scaled units) showed a significant increase at the end of dialysis compared to pre-dialysis. No significant change was observed in non-fluid removal patients. A moderate correlation was found between relative blood volume (RBV) and HF power (median R = 0.64, p 〈 0.05). This study suggests that ear PPG may be a suitable monitor of the systemic circulation and can provide a non-invasive tool to detect blood volume loss.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2010.5628035DOI Listing

Publication Analysis

Top Keywords

blood volume
12
removal patients
12
changes ear
8
relative blood
8
failure patients
8
fluid removal
8
non-fluid removal
8
hemodialysis
5
patients
5
respiration-induced changes
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!