Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In North America, an estimated 30,000 patients annually experience an aneurysmal subarachnoid hemorrhage (SAH). In approximately five percent of these patients, the hemorrhage is not visible on computerized tomography scans due to the inability to image blood at time intervals greater than 12 hours post symptom onset. For these patients (many of which have experience a sentinel hemorrhage that is a precursor to a more significant rupture) a method is needed for accurately analyzing cerebral spinal fluid (CSF) for evidence of SAH. Further, it is necessary to differentiate blood associated with the SAH from blood associated with the spinal tap procedure. This paper presents the development of a point-of-care device that is capable of performing such an analysis. The stand alone prototype device uses commercially available embedded system components to implement a hardware platform that is capable of collecting and analyzing optical absorbance spectra. A mathematical model for the hemorrhagic CSF sample is then developed using a PLSR based regression methodology that is able to differentiate between SAH and blood associated with the spinal tap. This differentiations in achieved by quantifying bilirubin (associated with the breakdown of old blood) in the CSF. Initial testing on the prototype device suggests that the device is able to quantify bilirubin in the presence of hemoglobin over concentrations ranges that are clinically relevant to the patient population of interest.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/IEMBS.2010.5627481 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!