Fast and accurate calibration of an X-ray imager to an electromagnetic tracking system for interventional cardiac procedures.

Annu Int Conf IEEE Eng Med Biol Soc

Philips Research North America, Briarcliff Manor, NY 10510, USA.

Published: March 2011

Cardiovascular disease affects millions of Americans each year. Interventional guidance systems are being developed as treatment options for some of the more delicate procedures, including targeted stem cell therapy. As advanced systems for such types of interventional guidance are being developed, electromagnetic (EM) tracking is coming in demand to perform navigation. To use this EM tracking technology, a calibration is necessary to register the tracker to the imaging system. In this paper we investigate the calibration of an X-ray imaging system to EM tracking. Two specially designed calibration phantoms have been designed for this purpose, each having a rigidly attached EM sensor. From a clinical usability point-of-view, we propose to divide this calibration problem into two steps: i) in initial calibration of the EM sensor to the phantom design using an EM tracked needle to trace out grooves in the phantom surface and ii) segmentation from X-ray images and 3D reconstruction of beads embedded in the phantom in a known geometric pattern. Combining these two steps yields and X-ray-to-EM calibration accuracy of less than 1 mm when overlaying an EM tracked needle on X-ray images.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2010.5627160DOI Listing

Publication Analysis

Top Keywords

calibration x-ray
8
electromagnetic tracking
8
interventional guidance
8
imaging system
8
tracked needle
8
x-ray images
8
calibration
7
fast accurate
4
accurate calibration
4
x-ray
4

Similar Publications

Purpose: The purpose of this study was to verify the effect of our previously proposed mesiodistal distance for multiple posterior implants on preserving peri-implant bone, and to provide a measurable criterion for predicting implant prognosis.

Methods: One hundred and two patients with dental implants placed in the posterior free-end edentulous arches were recruited in this cross-sectional study. Calibrated X-rays (peri-apical [PA] or bite-wing x-ray) were collected to measure the mesiodistal space as well as the corresponding bone resorption of implants after prosthesis placement.

View Article and Find Full Text PDF

Background: An increase in the prevalence of lung cancer that is not smoking-related has been noticed in recent years. Unfortunately, these patients are not included in low dose computer tomography (LDCT) screening programs and are not actually considered in early diagnosis. Therefore, improved early diagnosis methods are urgently needed for non-smokers.

View Article and Find Full Text PDF

Over the past decade, neuropathological diagnosis has undergone significant changes, integrating morphological features with molecular biomarkers. The molecular era has successfully refined neuropathological diagnostic accuracy; however, a substantial number of CNS tumor diagnoses remain challenging, particularly in children. DNA methylation classification has emerged as a powerful machine learning approach for clinical decision-making in CNS tumors.

View Article and Find Full Text PDF

Background: Accurate mortality prediction following transcatheter aortic valve implantation (TAVI) is essential for mitigating risk, shared decision-making and periprocedural planning. Surgical risk models have demonstrated modest discriminative value for patients undergoing TAVI and are typically poorly calibrated, with incremental improvements seen in TAVI-specific models. Machine learning (ML) models offer an alternative risk stratification that may offer improved predictive accuracy.

View Article and Find Full Text PDF

Purpose: The application of histotripsy, an emerging noninvasive, non-ionizing, and non-thermal tumor treatment, is currently limited by the inherent limitations of diagnostic ultrasound as the sole targeting modality. This study evaluates the feasibility and accuracy of cone beam computed tomography (CBCT) guidance for histotripsy treatments in an porcine model.

Materials And Methods: Histotripsy treatments were performed in the liver of seven healthy swine under the guidance of a C-arm CBCT system that was calibrated to the robotic arm of the histotripsy system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!