Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Intradyalitic exercise programas are important to improve patient's hemodynamic stability. Blood pressure and metabolic changes are correlated when heat accumulation is due to increment of the body core temperature (+1.0 °C). However, increase in temperature could be controlled by lowering dialysate's temperature using two main modalities techniques (isothermic and thermoneural) with different patient's thermal balance consequences, not yet well studied. In this work, a new method to observe the main physiological parameters (hearth rate variability (HRV), blood pressure, BTM dialysate temperature control and substrate utilization by indirect calorimtery) which are involved in hemodiafitration (HDF), are displayd. An experiment was carried out in a group of 5 patients waiting kidney transplant. In each patient, EE was assessed as well as the HRV during isothermic and thermoneutral modalities as a manner of cross and prospective study (a) at before therapy, (b) during therapy and (c) at the end of the HDF therapy. Power extraction was also measured by a BTM (Blood Temperature Monitor from Fresenius Inc), in order to determine how the dialysate temperature was controlled. The results showed important method's advantages which place the BTM performance as unstable control system with the possibility to produce undesirable HRV changes as the vagotonical response. However more patient cases are needed in order to identify the real advantage of this new method.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/IEMBS.2010.5625945 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!