Blood cardioplegia delivery systems are employed in most pediatric open heart cases to arrest the heart and keep it preserved during aortic cross-clamping. They are also used as part of a modified ultrafiltration system at the end of cardiopulmonary bypass. We evaluated and compared the air-handling capabilities of different types of blood cardioplegia delivery devices. A simple circuit incorporating a cardiotomy reservoir, a roller pump, a cardioplegia test system, and two emboli detection and classification sensors were used to investigate the air-handling capabilities of the following cardioplegia delivery systems: GISH Vision, Maquet Plegiox, Medtronic Trillium MYOtherm XP, Sorin Group BCD Vanguard, Sorin Group CSC14, and Terumo Sarns Conducer and Bubble Trap. The 0.25-in. circuit was primed with 400mL of Lactated Ringer's. Outdated packed red blood cells were added to obtain a hematocrit of 24-28%. System pressure was maintained at 50mmHg. Air (0.1, 0.3, 0.5mL) was injected at a speed of 0.1mL/s into the circuit just after the pump head. Gaseous microemboli (GME) were measured prior to the cardioplegia system and after the device to evaluate the air-handling characteristics. The tests were run at 100, 200, and 400mL/min blood flow for both 4 and 37°C. There were no significant differences among the groups when comparing precardioplegia delivery system GME, thus demonstrating that all devices received the same amount of injected air. When comparing the groups for postcardioplegia delivery system GME, significant differences were noted especially at the 400mL/min blood flow rate. These results suggest that for the devices compared in this study, the Maquet Plegiox and the Medtronic Trillium MYOtherm XP eliminated GME the best.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1525-1594.2010.01118.xDOI Listing

Publication Analysis

Top Keywords

cardioplegia delivery
16
air-handling capabilities
12
blood cardioplegia
12
delivery systems
12
maquet plegiox
8
plegiox medtronic
8
medtronic trillium
8
trillium myotherm
8
sorin group
8
400ml/min blood
8

Similar Publications

We conducted a high-risk redo mitral valve replacement through a right mini-thoracotomy without rib spreading (redo-MICS MVR) under systemic hyperkalemia combined with circulatory arrest to circumvent complications associated with cardioplegia delivery. The patient, a 75-year-old man, had a predicted mortality rate of 20%. Initial antegrade cardioplegia successfully induced cardiac arrest, which was administered every 30 min.

View Article and Find Full Text PDF

Objective: To evaluate actual myocardial energy requirements using indirect calorimetry, oxygen delivery (DO), oxygen extraction ratio (OER), cardiac output (CO) and their components, as well as to study the impact of positive inotropic agent (dobutamine) on myocardial metabolism in early postoperative period after cardiac surgery.

Material And Methods: We measured the main metabolic parameters using indirect calorimetry in 20 patients after on-pump cardiac surgery with cardioplegia. To evaluate the impact of metabolic load on CO, VO and DO, we administered dobutamine 3 µg/kg/min at the second phase of the study.

View Article and Find Full Text PDF

Redo extended thoracic aortic replacement from aortic root to descending aorta via anterolateral thoracotomy with partial sternotomy for graft infection.

Gen Thorac Cardiovasc Surg Cases

February 2024

Division of Cardiovascular Surgery, Department of Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, chuo-ku, Kobe, Hyogo, 650-0017, Japan.

A 59-year-old male underwent Bio-Bentall + total arch replacement with a frozen elephant trunk for acute type A aortic dissection before at another hospital. He was diagnosed as mediastinitis and previous graft infection, followed by wound closure with omental flap installation. However, the recurrent graft infection from the aortic root to the FET in the descending aorta was diagnosed by 18-fluorodeoxyglucose positron emission tomography.

View Article and Find Full Text PDF
Article Synopsis
  • Women with a history of hypertensive disorders during pregnancy face a significantly higher risk of major adverse cardiovascular events after undergoing coronary artery stenting compared to those without such a history.
  • In a study involving over 8,000 women, 13.4% reported hypertensive disorders, and after a median follow-up of 5 years, a notable percentage experienced severe cardiovascular outcomes.
  • The increased hazard rate for these women became evident after 4-8 years following the procedure, particularly impacting those with gestational hypertension.
View Article and Find Full Text PDF
Article Synopsis
  • Trauma during pregnancy poses risks for both the mother and fetus, necessitating interventions like resuscitative hysterotomy (RH) to improve maternal outcomes alongside fetal survival.
  • Recent studies indicate that RH can quickly restore maternal vital signs, making it crucial for patients with unstable conditions before cardiovascular collapse.
  • A case review of 4 pregnant trauma patients showed a 50% maternal survival and provided insights into the effectiveness of RH in emergency situations, highlighting a shift towards prioritizing maternal health.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!