Unlabelled: In the most recent decades, several developments have been made on impression materials' composition, but there are very few radiodensity studies in the literature. It is expected that an acceptable degree of radiodensity would enable the detection of small fragments left inside gingival sulcus or root canals.

Objective: The aim of this study was to determine the radiodensity of different impression materials, and to compare them to human and bovine enamel and dentin.

Material And Methods: Twenty-five impression materials, from 5 classes, were studied: addition and condensation silicones, polyether, polysulfides and alginates. Five 1-mm-thick samples of each material and tooth structure were produced. Each sample was evaluated 3 times (N=15), being exposed to x-ray over a phosphor plate of Digora digital system, and radiodensity was obtained by the software Digora for Windows 2.5 Rev 0. An aluminum stepwedge served as a control. Data were subjected to Kruskal-Wallis and Dunn's method (α=0.05).

Results: Different materials and respective classes had a different behavior with respect to radiodensity. Polysulfides showed high values of radiodensity, comparable to human enamel (p>0.05), but not to bovine enamel (p<0.05). Human dentin was similar only to a heavy-body addition silicon material, but bovine dentin was similar to several materials. Generally, heavy-body materials showed higher radiodensity than light-body ones (p<0.05).

Conclusion: Impression materials' radiodensity are influenced by composition, and almost all of them would present a difficult detection against enamel or dentin background in radiographic examinations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4246377PMC
http://dx.doi.org/10.1590/s1678-77572010000500007DOI Listing

Publication Analysis

Top Keywords

impression materials
12
bovine enamel
8
radiodensity
7
radiodensity evaluation
4
evaluation dental
4
impression
4
dental impression
4
materials
4
materials comparison
4
comparison tooth
4

Similar Publications

Background/purpose: Spacing between teeth is a common trait across different stages of dentition. With the tide of the digital impression, the scanning trueness of the intraoral scanner (IOS) is a hot subject. This study aimed to determine the correlation between the level of the spaced dentition and trueness of the intraoral scanning.

View Article and Find Full Text PDF

Background/purpose: The accuracy of intraoral scanners (IOSs) plays a crucial role in the success of final restorations in digital workflows. Previous studies have shown that numerous factors affect the accuracy of IOSs. Most studies have evaluated the accuracy of IOS under one restoration condition.

View Article and Find Full Text PDF

BACKGROUND A tooth preparation's clinical requirements and geometric configurations should take precedence over material characteristics when advocating for putty reline impression techniques for permanent restorations, since they require a technically sensitive spacer for light body elastomer. We evaluated the linear dimensional accuracy of vinyl polysiloxane-based putty reline impressions with different spacer acquisition techniques in short-span and long-span fixed partial dentures (FPD). MATERIAL AND METHODS A typodont tooth set simulated a 3-unit (short-span) and a 5-unit (long-span) FPD.

View Article and Find Full Text PDF

Wooden Plate Denture Reproduced Using Materials and Methods From 400 Years Ago.

Cureus

December 2024

Department of Oral and Maxillofacial Surgery, National Hospital Organization, Kyoto Medical Center, Kyoto, JPN.

This study aimed to reproduce a complete wooden plate denture, which was the first in the world to retain suction under negative pressure, using the same materials and methods from 400 years ago (i.e., the Edo period) to verify its masticatory performance.

View Article and Find Full Text PDF

Evaluating Cost-effectiveness and Mixing Efficacy for Elastomeric and Temporary Restorative Material Using Two Mixing Tips: A SEM-EDS Analysis.

J Contemp Dent Pract

September 2024

Department of Prosthodontics and Crown & Bridge, Bharati Vidyapeeth Deemed to be University, Dental College and Hospital, Pune, Maharashtra, India, ORCID: https://orcid.org/0009-0008-7338-1699.

Aim: This study aimed to compare the mixing efficacy and cost-effectiveness of new T-mixer tips against the standard double helical tips for a light-body elastomeric impression and a temporary/interim restorative material using a scanning electron microscope (SEM) and energy-dispersive X-ray spectroscopy.

Methodology: Automixed samples ( = 16) were divided into four groups of four samples each: Samples that were mixed with Helical tip for elastomer, T-mixer tip for elastomer, Helical tip for interim restorative material, and T-mixer tip for interim restorative material. These samples were then evaluated for SEM analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!