HIV clinics in Canada provide care to an increasing number of patients born outside of Canada with HIV-1 non-B subtype infections. Because the Easy Q HIV-1 v1.2 assay (EQ; bioMérieux) failed to detect some non-B subtype infections, a multiassay HIV-1 viral load (VL) study was conducted with patients with diverse HIV subtype infections. Patients were enrolled from the Southern Alberta HIV Clinic (SAC), Calgary, Alberta, Canada (n = 349) and the McGill HIV Clinic (MHC), Montreal, Quebec, Canada (n = 20) and had four or five tubes of blood drawn for testing by EQ and three other commercial HIV VL assays: (i) the Versant 3.0 HIV-1 test, with the Versant 440 instrument (branched DNA [bDNA]; Siemens), (ii) the RealTime HIV-1 test, with the m2000rt instrument (m2000rt; Abbott Molecular Diagnostics), and (iii) the COBAS AmpliPrep TaqMan HIV-1 48 test (CAP-CTM; Roche Molecular Diagnostics). Blood was processed according to the individual manufacturer's requirements and stored frozen at -86°C. The HIV subtype was known for patients who had undergone HIV genotypic resistance testing (Virco, Belgium). Data analyses were done using standard statistical methods within Stata 9.0 (StataCorp, College Station, TX). A total of 371 samples were tested on 369 patients, of whom 291 (81%) had a Virco genotype result of B (195; 53%) or non-B (96; 26%) subtypes A to D and F to K, as well as circulating recombinant forms (CRFs) (i.e., CRF01_AE and CRF02_AG). Most (58/78; 74%) patients of unknown subtype were recent African emigrants who likely have non-subtype B infection. Overall bias was small in pairwise Bland-Altman plots, but the limits of agreement between assays were wide. Discordant viral load results occurred for 98 samples and were due to missing values, false negatives, and significant underquantification that varied by HIV subtype. Results were obtained for all 371 samples with m2000rt, but for only 357 (97%) with CAP-CTM, 338 (92%) with EQ, and 276 (75%) with bDNA due to errors/equipment failures. False-negative results (nondetection of viral RNA versus other assay results) occurred for all platforms, as follows: for m2000rt, 8 (2%) [B(4) and non-B(4) subtypes], CAP-CTM, 9 (2.5%) [B(6) and non-B(3) subtypes]; EQ, 20 (6%) [B(7) and non-B(13) subtypes]; bDNA, 5 (2%) [B(1) and C(4)]. EQ and bDNA had the highest rates of underquantification by ≥ 1.0 log(10) copies/ml, mainly for HIV non-B subtypes. Performance significantly varied between HIV VL platforms according to subtype. HIV viral diversity in the population being tested must be considered in selection of the viral load platform.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3020439PMC
http://dx.doi.org/10.1128/JCM.00685-10DOI Listing

Publication Analysis

Top Keywords

hiv subtype
16
subtype infections
16
hiv
12
viral load
12
hiv-1 test
12
hiv-1
8
realtime hiv-1
8
hiv-1 viral
8
patients diverse
8
diverse hiv
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!