Measurement of bronchial and alveolar exhaled nitric oxide (NO) levels could be of clinical importance for the treatment of asthma. To discriminate between alveolar and bronchial NO, measurements need to be assessed at various flow rates. To study the feasibility, linearity, and long-term repeatability of NO measurements at four different exhalation flow rates in children with asthma. Twenty-one children with moderate persistent asthma, aged 6-12 yrs, were included in the study. NO was measured according to the ATS/ERS guidelines, using the NIOX analyzer with flow restrictors of 30, 50, 100, and 200 ml/s. Duration of the measurements ranged from 6-10 s, depending on the flow rate. The tests were repeated 3 and 6 months after the first NO measurement. Feasibility of NO measurements at these four flow rates increased from 67% to 91% and 95% at the first, second and third visit, respectively. A significant learning effect was present. Age and lung function indices did not influence success or failure of the tests. At the first measurements occasions, no problems occurred during the NO analysis at a 100 ml/s flow rate. There was a 75-90% success rate when performing the test using flow rates of 30, 50, and 200 ml/s. However, repeating the tests resulted in a 100% success rate. Measurements were not successful if: (i) children ran out of air; (ii) NO concentration exceeded 200 ppb; (iii) the measured NO flow was unstable; and (iv) the NO plateau was not formed. This study showed good feasibility and linearity of NO measurements in asthmatic children of 6 yrs and over at flow rates between 50-200 ml/s. A significant learning effect was present. The long-term reproducibility of alveolar and bronchial NO values during 6 months was moderate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1399-3038.2009.00874.x | DOI Listing |
Echocardiography
January 2025
Cardiology Department, Soroka University Medical Center, Beer-Sheba, Israel.
Background: Timing of treatment of aortic stenosis (AS) is of key importance. AS severity is currently determined by transthoracic echocardiography (TTE) with a main focus on mean trans-aortic gradients. However, echocardiography has its limitations.
View Article and Find Full Text PDFNeth Heart J
January 2025
Department of Cardiology, Leiden University Medical Centre, Leiden, The Netherlands.
Objectives: Coronary graft failure (CGF) may occur early after coronary bypass graft surgery (CABG). The study aimed to identify clinical and perioperative risk factors and to evaluate the long-term clinical impact of symptomatic early CGF.
Methods: Patients who underwent clinically indicated coronary angiography (CAG) prior to post-CABG discharge between 2012 and 2022 were included.
Immunol Res
January 2025
Immunology Laboratory, Department of Physiology, University Colleges of Science and Technology, University of Calcutta, 92 APC Road, Calcutta, 700009, West Bengal, India.
Septic arthritis (SA) caused by Staphylococcus aureus is a severe inflammatory joint disease, characterized by synovitis accompanied with cartilage destruction and bone erosion. The available antibiotic treatment alone is insufficient to resolve the inflammation that leads to high rates of morbidity and mortality. Among the CD4 T helper lymphocytes, the Th17 and Tregs are key regulators of immune homeostasis.
View Article and Find Full Text PDFAnn Emerg Med
January 2025
Department of Emergency Medicine, Medical University of Vienna, Vienna, Austria. Electronic address:
Study Objective: Extracorporeal cardiopulmonary resuscitation (eCPR) is a rescue therapy for selected patients when conventional cardiopulmonary resuscitation (CPR) fails. Current evidence suggests that the success of eCPR depends on well-structured in- and out-of-hospital protocols. This article describes the Vienna eCPR program, and the interventions implemented to improve clinical processes and patient outcomes.
View Article and Find Full Text PDFAnal Chem
January 2025
Shanxi Key Lab for Modernization of TCVM, College of Veterinary Medicine, Shanxi Agricultural University, Taiyuan 030000, Shanxi, P. R. China.
Microfluidics is an emerging technology for buffer exchange in bioprocessing applications. However, achieving buffer exchange with simplicity of operation and high throughput in a straightforward channel design remains a challenge. This study presents a novel semicircular microchannel design that allows for the deterministic regulation of helical and Dean vortices through geometric confinement.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!