Use of helical TomoTherapy-based MVCT imaging for adaptive planning is becoming increasingly popular. Treatment planning and dose calculations based on MVCT require an image value to electron density calibration to remain stable over the course of treatment time. In this work, we have studied the dosimetric impact on TomoTherapy treatment plans due to variation in image value to density table (IVDT) curve as a function of target degradation. We also have investigated the reproducibility and stability of the TomoTherapy MVCT image quality over time. Multiple scans of the TomoTherapy "Cheese" phantom were performed over a period of five months. Over this period, a difference of 4.7% in the HU values was observed in high-density regions while there was no significant variation in the image values for the low densities of the IVDT curve. Changes in the IVDT curves before and after target replacement were measured. Two clinical treatment sites, pelvis and prostate, were selected to study the dosimetric impact of this variation. Dose was recalculated on the MVCTs with the planned fluence using IVDT curves acquired before and after target change. For the cases studied, target replacement resulted in an overall difference of less than 5%, which can be significant for hypo-fractionated cases. Hence, it is recommended to measure the IVDT curves on a monthly basis and after any major repairs/replacements.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5720397 | PMC |
http://dx.doi.org/10.1120/jacmp.v11i4.3229 | DOI Listing |
Phys Med
March 2015
Department of Radiotherapy, Institut Bergonié, Comprehensive Cancer Centre, F-33000 Bordeaux, France. Electronic address:
Purpose: We aimed to identify the most accurate combination of phantom and protocol for image value to density table (IVDT) on volume-modulated arc therapy (VMAT) dose calculation based on kV-Cone-beam CT imaging, for head and neck (H&N) and pelvic localizations.
Methods: Three phantoms (Catphan(®)600, CIRS(®)062M (inner phantom for head and outer phantom for body), and TomoTherapy(®) "Cheese" phantom) were used to create IVDT curves of CBCT systems with two different CBCT protocols (Standard-dose Head and Standard Pelvis). Hounsfield Unit (HU) time stability and repeatability for a single On-Board-Imager (OBI) and compatibility of two distinct devices were assessed with Catphan(®)600.
J Appl Clin Med Phys
September 2012
Department of Medical Physics, Centre Oscar Lambret, 3, Rue Frédéric Combémale, 59020 Lille, France.
The purpose of this investigation was the creation of a new protocol allowing more precise dose calculations on megavoltage CT (MVCT) images for tomotherapy, both for adaptive and StatRT planning. Daily MVCT images offer, next to positioning purposes, the possibility for daily dose check and adaptive planning. Dose calculations use the image value to density table (IVDT) to calculate physical densities from Hounsfield Units (HUs).
View Article and Find Full Text PDFRadiol Oncol
September 2011
Department of Human Oncology, University of Wisconsin, Madison, WI, USA.
Background: We have analyzed the stability of CT to density curve of kilovoltage cone-beam computerized tomography (kV CBCT) imaging modality over the period of six months. We also, investigated the viability of using image value to density table (IVDT) generated at different time, for adaptive radiotherapy treatment planning. The consequences of target volume change and the efficacy of kV CBCT for adaptive planning issues is investigated.
View Article and Find Full Text PDFJ Appl Clin Med Phys
July 2010
Department of Human Oncology, University of Wisconsin, Madison, Wisconsin 53792, USA.
Use of helical TomoTherapy-based MVCT imaging for adaptive planning is becoming increasingly popular. Treatment planning and dose calculations based on MVCT require an image value to electron density calibration to remain stable over the course of treatment time. In this work, we have studied the dosimetric impact on TomoTherapy treatment plans due to variation in image value to density table (IVDT) curve as a function of target degradation.
View Article and Find Full Text PDFCongest Heart Fail
August 2010
Department of Cardiology, Kosuyolu Heart and Research Hospital, Istanbul, Turkey.
The authors investigated the left ventricular systolic dyssynchrony (LVSD) parameters in nonischemic dilated cardiomyopathy (DCM) by tissue Doppler echocardiography. A total of 56 DCM patients with normal sinus rhythm and 15 controls were recruited. The patients were subgrouped according to QRS duration (QRSd): QRSd
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!