This paper presents a new shear wave velocity imaging technique to monitor radio-frequency and microwave ablation procedures, coined electrode vibration elastography. A piezoelectric actuator attached to an ablation needle is transiently vibrated to generate shear waves that are tracked at high frame rates. The time-to-peak algorithm is used to reconstruct the shear wave velocity and thereby the shear modulus variations. The feasibility of electrode vibration elastography is demonstrated using finite element models and ultrasound simulations, tissue-mimicking phantoms simulating fully (phantom 1) and partially ablated (phantom 2) regions, and an ex vivo bovine liver ablation experiment. In phantom experiments, good boundary delineation was observed. Shear wave velocity estimates were within 7% of mechanical measurements in phantom 1 and within 17% in phantom 2. Good boundary delineation was also demonstrated in the ex vivo experiment. The shear wave velocity estimates inside the ablated region were higher than mechanical testing estimates, but estimates in the untreated tissue were within 20% of mechanical measurements. A comparison of electrode vibration elastography and electrode displacement elastography showed the complementary information that they can provide. Electrode vibration elastography shows promise as an imaging modality that provides ablation boundary delineation and quantitative information during ablation procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3066053PMC
http://dx.doi.org/10.1109/TMI.2010.2091412DOI Listing

Publication Analysis

Top Keywords

shear wave
20
wave velocity
20
electrode vibration
16
vibration elastography
16
boundary delineation
12
velocity imaging
8
ablation procedures
8
good boundary
8
velocity estimates
8
mechanical measurements
8

Similar Publications

Validation of Muscle Ultrasound Speckle Tracking and the Effect of Nordic Hamstring Exercise on Biceps Femoris Displacement.

Ultrasound Med Biol

January 2025

School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Taipei, Taiwan ROC; Center of Physical Therapy, National Taiwan University Hospital, Taipei, Taiwan ROC. Electronic address:

Objective: This study aimed to validate the ultrasound speckle tracking (UST) algorithm, determine the optimal probe location by comparing normalized cross-correlation (NCC) values of muscle displacement at two locations (proximal vs. middle) of the biceps femoris long head (BFlh) using the UST, and investigate the effects of Nordic hamstring curl exercise (NHE) training on BFlh displacement.

Methods: UST efficacy was verified with ex vivo uniaxial testing of porcine leg muscles.

View Article and Find Full Text PDF

Joint Analysis of Cardiovascular Control and Shear Wave Elastography to Determine Carotid Plaque Vulnerability.

J Clin Med

January 2025

Operative Unit of Vascular Surgery, IRCCS Policlinico San Donato, 20097 San Donato Milanese, Italy.

: Carotid artery stenosis (CAS) is one of the main causes of stroke, and the vulnerability of plaque has been proved to be a determinant. A joint analysis of shear wave elastography, a radiofrequency echo-based wall tracking technique for arterial stiffness evaluation, and of autonomic and baroreflex function is proposed to noninvasively, preoperatively assess plaque vulnerability in asymptomatic CAS patients scheduled for carotid endarterectomy. : Elastographic markers of arterial stiffness were derived preoperatively in 78 CAS patients (age: 74.

View Article and Find Full Text PDF

The aim of this study was to investigate the accuracy in fibrosis staging of a novel shear wave elastography (SWE) device (S-Shearwave Imaging by Samsung) and a previously validated 2D-SWE by Supersonic Imagine (SSI) in patients with biopsy proven metabolic dysfunction-associated steatotic liver disease (MASLD). This prospective study included 75 consecutive patients with MASLD who underwent liver biopsy for suspected MASH. All patients underwent S-Shearwave Imaging by Samsung and 2D-SWE with SSI on the same day of liver biopsy.

View Article and Find Full Text PDF

Diagnostic Accuracy of Shear Wave Elastography in Predicting Malignant Origins of Pleural Effusions in Emergency Departments.

Diagnostics (Basel)

January 2025

Odense Respiratory Research Unit (ODIN), Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, 5000 Odense, Denmark.

: Ultrasound is a valuable diagnostic tool in the diagnostic work-up of dyspnea and can identify even small pleural effusions. The incorporation of shear wave elastography (SWE) represents a possible tool in stratifying pleural effusions by the risk of underlying malignancy. No previous studies on ultrasound with the incorporation of SWE have been conducted in an emergency department (ED), where such stratification might have a clinical impact by hastening referrals for the diagnostic work-up of underlying malignancy.

View Article and Find Full Text PDF

Shear wave elastography for the evaluation of children with chronic kidney disease: promising, but insufficient.

Pediatr Nephrol

January 2025

Department of Nephrology, Key Laboratory of Major Diseases in Children, Ministry of Education, National Center for Children's Health, Beijing Children's Hospital, Capital Medical University, Beijing, China.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!