Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.hrthm.2010.11.014 | DOI Listing |
Introduction: Reports of pseudoaneurysms associated with biliary self-expandable metallic stent (SEMS) placement have been increasing. Recently, cases of hepatic pseudoaneurysm rupture caused by double pigtail plastic stents (DPS) have also been reported. The symptoms of pseudoaneurysms are often non-specific, and many cases are diagnosed only after rupture.
View Article and Find Full Text PDFCureus
December 2024
Surgery, Memorial University of Newfoundland, St. John's, CAN.
Concurrent malignant biliary and gastric outlet obstruction requires urgent palliative intervention to improve patient quality of life and permit systemic therapy. Traditional management has been surgical gastrojejunostomy and hepaticojejunostomy, two morbid procedures. Comparatively, endoscopic stenting can relieve both sites of obstruction with less complications and quicker recovery.
View Article and Find Full Text PDFJ Clin Exp Hepatol
November 2024
Department of Radiodiagnosis, All India Institute of Medical Sciences, Bhubaneswar, Odisha, 751019, India.
Suspicion of vascular injury during endoscopic retrograde cholangiopancreatography (ERCP) should be raised in the event of intraprocedural bleeding, persistent hyperbilirubinemia, and sepsis despite biliary stenting. Most inadvertent portal vein (PV) cannulations during ERCP are innocuous, and mere withdrawal of guidewire and catheter suffices. However, unintentional PV stenting, particularly with larger metallic stents, increases the likelihood of significant bleeding.
View Article and Find Full Text PDFJ Clin Med
January 2025
Interventional Radiology Department, Adana Dr. Turgut Noyan Application and Research Center, Başkent University, 01250 Adana, Turkey.
: The objective of the current research is to assess the benefits that come with antegrade ureteral stenting coupled with imaging techniques in children and also provide a new classification based on the ureter's morphological elements. : Between 2011 and 2024, 107 antegrade stent placement procedures performed in 71 pediatric patients aged 0-12 years who could not undergo retrograde double-J stent placement were retrospectively analyzed. According to the morphologic structure of the ureter, four categories were classified as normal, straight/slightly angled, S-shaped, and spiral-shaped.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
September 2024
Division of Cardiovascular Surgery, University of Pennsylvania, Philadelphia, Pennsylvania.
Background: Continuous retrograde flow across the aortic valve from left ventricular assist device (LVAD) therapy can result in cusp damage and progressive aortic regurgitation, potentially triggering recurrent heart and multiorgan failure. The management of aortic regurgitation after LVAD implantation has not been well defined.
Methods: This study retrospectively reviewed the investigators' experience with the management of de novo aortic regurgitation requiring intervention in patients with continuous-flow LVAD.