To evaluate the reliability of pulse oximetry during exercise, we studied 101 patients primarily with chronic pulmonary diseases. Three devices were used on different patients. Radial arterial blood was sampled at rest and maximal exercise simultaneously to pulse oximetric determination. Measured blood oxygen saturation was significantly different from noninvasive saturation at rest and also at exercise for each device. Nevertheless, changes in pulse oximetry from rest to exercise were significantly correlated with measured saturation for all three devices. Direction of changes in saturation from rest to exercise was correctly evaluated by transcutaneous oximetry in all but six instances where changes were less than 4 percent. Although measured and transcutaneous saturations are significantly different, we conclude that pulse oximetry reliably estimates changes in arterial saturation between rest and exercise for a clinical purpose. None of the three tested devices was better compared with the others in estimating saturation changes at exercise.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1378/chest.97.3.635 | DOI Listing |
Case Rep Dent
January 2025
Institute of Dentistry and Oral Sciences, Faculty of Medicine, Palacky University, Olomouc, Czech Republic.
The outcome of tooth autotransplantation depends mainly on the transplant tooth's anatomy-the type of donor tooth and the developmental stage of root formation. Mature teeth display a higher complication rate due to lower pulp revascularization potential, requiring root canal treatment (RCT) pre- or postoperatively to avoid postoperative complications, which extends treatment duration and cost. This report details a 39-year-old patient's autotransplantation of a mature wisdom tooth to replace the first molar after unsuccessful root canal retreatment.
View Article and Find Full Text PDFJ Am Geriatr Soc
January 2025
Johns Hopkins School of Medicine, Baltimore, Maryland, USA.
Sensors (Basel)
January 2025
Research Centre for Biomedical Engineering, City St George's, University of London, London, EC1V 0HB, UK.
Over the past ten years, there has been an increasing demand for reliable consumer wearables as users are inclined to monitor their health and fitness metrics in real-time, especially since the COVID-19 pandemic. Reflectance pulse oximeters in fitness trackers and smartwatches provide convenient, non-invasive SpO measurements but face challenges in achieving medical-grade accuracy, particularly due to difficulties in capturing physiological signals, which may be affected by skin pigmentation. Hence, this study sets out to investigate the influence of skin pigmentation, particularly in individuals with darker skin, on the accuracy and reliability of SpO measurement in consumer wearables that utilise reflectance pulse oximeters.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Research Centre for Biomedical Engineering, City St George's, University of London, London EC1V 0HB, UK.
The effect of skin pigmentation on photoplethysmography and, specifically, pulse oximetry has recently received a significant amount of attention amongst researchers, especially since the COVID-19 pandemic. With most computational studies observing overestimation of arterial oxygen saturation (SpO) in individuals with darker skin, this study seeks to further investigate the root causes of these discrepancies. This study analysed intensity changes from Monte Carlo-simulated reflectance PPG signals across light, moderate, and dark skin types at oxygen saturations of 70% and 100% in MATLAB R2024a.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.
(1) Background: To develop a novel capillary refill time measurement system and evaluate its reliability and reproducibility. (2) Methods: Firstly, the utilization of electromagnetic pressure technology facilitates the automatic compression and instantaneous release of the finger. Secondly, the employment of pressure sensing technology and photoelectric volumetric pulse wave analysis technology enables the dynamic monitoring of blood flow in distal tissues.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!